8
Dismantling and fitting
8.8

Removing the cartridge group

Mark the casing position for assembly.
Do not remove oil orifice (if present)
To limit the oil flow rate through the bearing casing during operation (engine under load) to the
admissible values, an oil orifice is mandatory at the oil inlet of the bearing casing if the oil inlet
pressure is > 3 bar (overpressure).
If an oil orifice is fitted in the oil inlet of the bearing casing, it must not be removed.
Figure 35: Oil orifice
01 Bearing casing
02 Oil orifice
03 Circlip
Removing the insulation
Figure 36: Removing insulation sheets
Remove the insulation sheets (01, 02, 03).
© Copyright 2017 ABB. All rights reserved.
HZTL4032_EN
Page 80 / 120
Revision F
January 2017