Active Test Program - Whirlpool 6ADP905/3 WH Service Manual

Table of Contents

Advertisement

WHIRLPOOL CONSUMER SERVICES

ACTIVE TEST PROGRAM

Start the active test procedure by first running the passive test then press the start button for
less than three seconds.
Operation
Start
Backrinsing
(only after
second run of
test program
Filling
Washing
Pumpout
End
Function
Fill and pump
at the same
time (flushing)
three times, 15
seconds each
time
Fills, spray
pump starts &
continues to
fill. Fill stops,
pump stops for
3 sec.
Detergent
dispenser
operates,
pump restarts,
5 sec delay
then heating
starts
Water heated
to 65°C
30 sec delay
Pumpout
PS4 LED on
Models 6ADP905/3 WH
Notes :
When the machine detects a fault during
normal operation the start light will begin to
flash and the cycle may or may not stop.
When the control knob is turned to zero the
fault is stored (except Fault Code F6) and
the fault code will be displayed when the
passive test is run. For the diagnostics to
locate fault code F6, the active test
procedure MUST be followed.
The active test programs runs for
approximately 21 minutes or, if the heat cycle
is bypassed the test runs for approximately 3
minutes and 45 seconds.
The active test program runs to the point of
failure then stops. If there is no failure the
test programs runs to the end.
The failure position is indicated by the
flashing START LED extinguishing.
To exit the test program, press the START
button for more than three seconds.
An empty rinse aid container will not
cause the test program to stop, only
illuminate the red LED.