Errata
7.
RAID Card Physical Device numbers are not reset
The Intel® Storage Server SSR212MC2R and SSR212MC2RBR's RAID card Physical
Problem:
Device (PD) numbering is not reset to 0 thru 11.
The RAID card PD numbers may not start at 0 thru 11, as they should. They could start
Implication:
at 12 thru 23, or 24 thru 35, etc. depending upon which test suites the system was
subject to at the factory. There is no negative consequence, just an FYI that the
numbering could be different from system to system.
None.
Workaround:
Fixed.
Status:
8.
Some versions of Enclosure Management Firmware do not support
Quad Core Xeon™ processors
The Intel® Storage Server SSR212MC2R's Enclosure Management (EM)
Problem:
Firmware (FW) may not support Quad Core processors.
If your Intel® Storage Server SSR212MC2R has EM FW -30 or -45, it will not
Implication:
support Quad core processors properly.
The 2nd core pairs are not monitored for temperature, and may throttle without
causing any increase in fan speed, resulting in possible performace degradation.
Ignore the alarms/errors, or install EM FW -1.0.3-55 or later.
Workaround:
Fixed in Enclosure Management FW release 1.0.3-55.
Status: