Siemens SIMATIC S7 User Manual page 85

Simatic automation tool v2.1
Hide thumbs Also See for SIMATIC S7:
Table of Contents

Advertisement

Property Name
IP
IPString
MAC
MACString
MemoryResetAllowed
Modules
Name
NewFirmwareVersion
NewDefaultGateway
NewIP
NewProfinetName
NewProgramName
NewRestoreName
ProfinetName
ProgramUpdateAllowed
ResetToFactoryAllowed
RestoreAllowed
Selected
SerialNumber
Slot
SlotName
StationNumber
SubSlot
Supported
SIMATIC Automation Tool V2.1 user guide
Manual, V2.1.1 07/2016, A5E33042676-AC
SIMATIC Automation Tool API for .NET framework
Return Type
Description
uint
The IP Address of the device, represented as an
unsigned integer. The encoded IP Address uses
one byte to represent each decimal value in the IP
Address. For example, the encoded value
0xC0A80001 is equivalent to the more common
string representation of "192.168.0.1"
string
The IP Address of the device, represented as a
string in the form "xx.xx.xx.xx"
ulong
The unique MAC assigned to the device. The
encoded MAC address uses one byte to encode
each of the 6 octets defined for the address. For
example, the encoded MAC address
0x112233445566 is equivalent to the more com-
mon string representation of "11:22:33:44:55:66"
string
The unique MAC assigned to the device, repre-
sented as a string in the form "11:22:33:44:55:66".
FeatureSupport
Does the device support a memory reset?
IModuleCollec-
A collection of the modules plugged on the station.
tion
See also IModuleCollection class (Page 116)
string
The name of the device.
string
These properties are used in the SIMATIC Auto-
string
mation Tool user interface are not relevant for API
string
operations.
string
string
string
The PROFINET name for the device.
FeatureSupport
Does the device support a program update?
FeatureSupport
Does the device support reset to factory settings?
FeatureSupport
Does the device support the restore features?
bool
This property is used in the SIMATIC Automation
Tool user interface and is not relevant to API op-
erations.
string
The unique serial number for the device
uint
The slot number for the hardware item
string
This property is used in the SIMATIC Automation
Tool user interface and is not relevant to API op-
erations.
uint
The station number of the device
uint
The subslot of the device: This value is used for
pluggable submodules such as SB-1200.(Signal
Board).
bool
Is the detected network device supported by cur-
rent SIMATIC Automation Tool API operations?
6.7 The IProfinetDevice interface