Siemens SIMATIC S7 User Manual page 41

Simatic automation tool v2.1
Hide thumbs Also See for SIMATIC S7:
Table of Contents

Advertisement

Preparing firmware update files for use with the SIMATIC Automation Tool
● You can obtain firmware update software from the customer support
(https://www.siemens.com/automation/) web site.
● Another option is to go directly to a device's customer support web page by right-clicking
with the mouse cursor on a device row and then selecting the menu item "Check for
updates". The Siemens support web page selection is controlled by the article number
displayed in a device table row. For example, a "Check for updates" command on article
number 6ES7 215-1HG31-0XB0 links to the corresponding S7-1215C web support page
(https://support.industry.siemens.com/cs/products/6es7215-1hg31-0xb0/cpu-1215c-
dcdcrly-14di10do2ai2ao?pid=79072&dtp=Download&mlfb=6ES7215-1HG31-
0XB0&lc=en-WW)
For a CPU example, the firmware update file named 6ES7211_1AE40_0XB0_V04.00.02.exe
is only for the S7-1200 CPU 1211C DC/DC/DC model. If you use the .upd file within this
package for any other S7-1200 CPU model, the update process will fail.
When you execute the update file and extract the files, you will see the following set of files
and folders.
● file: S7-JOB.SYS
● folder: FWUPDATE.SYS contains the .upd file.
– file: 6ES7 211-1AE40-0XB0 V04.00.02.upd (.upd file used by the SIMATIC
For an I/O module example, the firmware update file named 232-4HD32-0XB0_V203.exe is
only for the S7-1200 SM1232 ANALOG OUTPUT 4AO module. The self-extracting .exe file
contains the file 6ES7 232-4HD32-0XB0 V02.00.03_00.00.00.00.upd that is used by the
SIMATIC Automation Tool.
Note
New format firmware update files
• The self-extracting .exe update package name must refer to the article number of the
device that you want to update.
• The extracted .upd file name must match the article number of the device and the
firmware version that you want to load.
Note
Old format firmware update files
• The self-extracting .exe update package name must refer to the article number of the
device that you want to update.
• Contains three or more files depending on the firmware size.
• Create a folder with any name underneath the C:\ProgramData\Siemens\SIMATIC
Automation Tool\Firmware folder. You can name the folder with the article number and
version number so it will be easier to identify, but you can use any name. The SIMATIC
Automation Tool parses all firmware files at startup to confirm exact firmware version
numbers.
SIMATIC Automation Tool V2.1 user guide
Manual, V2.1.1 07/2016, A5E33042676-AC
Automation Tool)
3.8 Install new firmware in CPUs and modules
Tool operations
41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents