Review this chart to find do-it-yourself solutions for minor performance problems.
Any service or repair needed, other than as described in this Use & Care Guide,
should be performed through your local LGE service center.
WARNING
Electrical shock and personal injury hazard.
Always unplug the vacuum cleaner before servicing. Failure to do so could result in
electrical shock or personal injury.
PROBLEM
Vacuum cleaner will
not run
Agitator does not
turn
Dust escapes the
dust tank
Poor dirt pickup

TROUBLESHOOTING

POSSIBLE CAUSE
• Unplugged at wall outlet
• Batteries are dead
• Thermal overload
protection activated
• Switch is off (unit is in
bare floor mode)
• Cleaner is in upright
position
• Agitator Reset switch is
tripped (brush is jammed)
• Belt broken
• Dust tank improperly
installed
• Pre-filter cover not closed
• Tank bottom is not
latched
• Full or clogged dust tank
• Dust tank improperly
installed
• Wand not installed
properly
• Clogged hose or nozzle
• Belt broken/not installed
properly
• Thermal protector
activated
• Agitator overload
protector activated
• Hole in hose
• Worn agitator
-23-
POSSIBLE SOLUTION
• Make sure cord is plugged into a
functioning outlet
• Replace batteries see page 20
• Allow the vacuum cleaner to cool
down. See page 15
• Turn on agitator power switch
• Press handle release pedal and tilt
unit back
• Unplug the vacuum cleaner and check
the agitator for obstructions and reset
the unit. See Page 15
• Replace belt. See page 20
• Make sure all dust tank components
and filters are installed correctly
• Check pre-filter cover
• Make sure tank bottom is closed and
latched
• Empty dust tank and clean filters
• Make sure all dust tank components
and filters are installed correctly
• Make sure the wand is installed
correctly
• Check for clogs. See page 21
• Check belt, and replace if needed.
See page 20
• Allow the vacuum cleaner to cool
down. See page 15
• Unplug the vacuum cleaner and check
the agitator for obstructions. Press the
reset button
• Inspect hose carefully.
Replace if needed
• Contact service

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents