Page 2
2. All non-wear item parts purchased after warranty expiration are warranted for 90 days. 3. Warranty starts from the date of sale to the consumer or, at Tornado’s discretion, 6 months after the dealer purchased the unit from Tornado, whichever comes first.
Use this unit only as described in this manual. Use only manufacturer’s recommended attachments. To reduce the risk of personal injury or damage to your unit use only Tornado recommended accessories. When using an electrical appliance, basic precautions should always be followed including the...
115V 115V AMPS CERTIFICATION All Specifications Subject to Change Without Notice. All information and specifications printed in this manual are current at the time of printing. However, because of Tornado’s policy of continued product improvement, we reserve the right to make changes at any time without notice. Product Specifications Model CFV10...
The machine will provide years of satisfactory service if operated and maintained according to recommendations in the manual. If additional information is needed, please write to: 800-VACUUMS Tornado Industries, LLC 3101 Wichita Court FAX 817-551-0719 Fort Worth, TX 76140...
Page 7
To begin operating your Critical Filter Vacuum 10. When finished, remove the hose by pushing (CFV), perform the following steps. in on the RED button and pulling out on the hose 1. Ensure all filters are in place and properly se- (Fig. 3) cured. 2. Place the head assembly on top of the tank 3. Engage the latches by pressing down (fig. 1) Fig. 3 To Change Filters 1. Ensure the unit is turned off and unplugged be- Fig.
Page 8
5. Remove paper filter by stretching the top ATTACHMENT SET elastic, carefully, over the cloth filter (Fig. 5) Fig. 5 6. Loosen the clamp holding the cloth filter and remove the filter (Fig. 6) 1. Floor Tool p/n WD112 2. Extension (2 pcs) p/n WD29 3. Dust Brush p/n WD33 4. Crevice Tool p/n WD32 5. Hose p/n TBD 6. Wand p/n WD28 Fig. 6 CFV10 7. Remove the HEPA filter. (Fig. 7) Collection Bag (3/pkg) 90032 Paper Bag (12/pkg) 98588 Cloth Bag (1/pkg) 98595 HEPA Filter (1/pkg) 90616...
TROUBLESHOOTING LOSS OF SUCTION CAUSE SOLUTION Tank full Empty tank Clogged hose or wand Remove obstruction Loose or broken fan Contact service center Motor not working Contact service center Seal worn Replace seal MOTOR IS NOT RUNNING CAUSE SOLUTION Broken switch Contact service center Defective power cord Contact service center...
Need help?
Do you have a question about the TASKFORCE 97060 CFV 10 and is the answer not in the manual?
Questions and answers