3-2 Main Procedure

No
Symptom
1
No Power
2
Auto Shut Down
3
No Light On
- Ensure the Power Cord and AC Power Outlet are securely
connected
- Ensure all connectors are securely connected and aren't
broken
- Check LVPS
- Check Main Board
- Ensure the projector is not put on a soft pad and the air vent is
not blocked.
a. Lamp failed:Power LED( flashes red),Lamp LED lights red
- Check Lamp
- Check LVPS
- Check Main Board
b. Fan failed:Power LED (flashes red), Temp LED (flashes
red)
- Check whether have execute Fan Calibration
- Check Fan
- Check Main Board
- Check Color Wheel Module
- Check Photo Sensor Board
c. Over Temp:Power LED (flashes red),Temp LED lights red
- Check Fan
- Check Main Board
- Ensure all connectors are securely connected and aren't
broken
- Check Lamp Cover, Intelock Switch
- Check Lamp Module
- Check LVPS
- Check Main Board
- Check Color Wheel
- Check Photo Sensor Board
Procedure
Lamp LED lights red
Confidential
S310e/X312