INSTALLATION (continued)
Remove a side panel from the base assembly to gain access to the bridge rectifier of one of the
xenon power supplies. Use either the positive (red) or negative (black) lead at the top of the rectifier heat
sink as a connection point for the clamp-on ammeter. Voltage measurements can be taken at the hex
head screws connecting the red (+) and black (-) leads to their respective heat sinks. Observe all due
safety precautions when taking voltage and current readings in a power "ON" condition.
Indicator Lights,
Phase Detection
2
OPERATOR'S CONTROL PANEL
Circuit Breaker, Auxilliary Power
Toggle Switch, POWER ON-OFF
Pushbutton Switch,
IGNITE
Elapsed Time Meter
(HOURS)
Toggle Switch,
FOCUS IN-OUT