ABB-Welcome
Pos: 26 /Di nA4 - A nleitu ngen Onlin e/Ueb ersc hrift en/2 ./Bedie nakti onen @ 2 0\m od_ 1323 262 294 281 _15. docx @ 11 191 1 @ 2 @ 1
4.2
Setting
Pos: 27 /Di nA4 - A nleitu ngen Onlin e/Ueb ersc hrift en/3 ./Spr ech- und Videov erbi ndu ng @ 20\ mod _13 232 6236 870 0_1 5.do cx @ 1119 27 @ 3 @ 1
4.2.1
Set indoor station address (X200, X100)
Pos: 28 /Di nA4 - A nleitu ngen Onlin e/In halt/KNX/Do orEnt ry/83 220 -AP-xxx/Sp rech - u nd Vide over bind ung - 8 322 0-AP-xxx @ 20\ mo d_1 3232 623 418 52_ 15.d ocx @ 111 919 @ @ 1
Step 1: Hold "light"
Step 2: Hold "talk"
Step 3: Press "mute"
The value is indicated by LED of each button.(Default value =0)
LED "talk" flashes, 0xx.
LED "unlock" flashes, 1xx.
LED "light" flashes, 2xx;
Step 4: Hold "light"
4.2.2
Set function of light button
Step 1: Hold "light"
Step 2: Hold "unlock"
Step 3: Press "mute"
The value is indicated by LED of each button.(Default value =0)
LED "talk" flashes, switching the lighting.
LED "unlock" flashes, opening the second lock.
LED "light" flashes, room to room intercom.
LED "mute" flashes, call guard unit.
Step 4: Hold "light"
|
button for 3s to enter setting mode. (4 LEDs are on)
button for 3s to enter the setting of X200/X100.
button to change the number.
.
24
button for 3s to enter setting mode (4 LEDs are off)
button for 3s to enter setting mode (4 LEDs are on)
button for 3s to enter the setting of light button.
button to change the function.
button for 3s to enter setting mode (4 LEDs are off)
024
124
224
— 7 —