Vent Free Features; Fresh Air Requirements - Monessen Hearth SD30PV Installation & Operating Manual

Sundance vent free gas heater
Table of Contents

Advertisement

I. Vent Free Features
The Sundance Vent Free gas stove is an unvented gas heating
appliance tested and listed to the ANSI standard Z21.11.2,
Latest Edition. This appliance is specifically configured to
burn either Natural Gas or Propane fuel, as indicated on the
metal rating plate attached to the rear shroud. The Sundance
is not fuel convertible.
The stove is shipped fully assembled and ready for installation.
The stove is equipped with an SIT control valve that allows
thermostatic control, on/off switch or a remote switch (not
supplied).
Both models incorporate variable regulators that allow you to
adjust burner heat output between HIGH, (28,000 Btu), and
LOW, (19,500 Btu). See the Operation Section for details.
The standing pilot incorporates an Oxygen Depletion System
(ODS/pilot) designed to shut off the appliance if enough fresh
air is not available.
J. Fresh Air Requirements
Fresh Air Requirements for Combustion and Ventilation:
Modern construction standards have resulted in homes that
are highly energy-efficient and that allow little heat loss.
Your home needs to breathe, however, and all fuel-burning
appliances within it require fresh air in order to function properly
and safely. Exhaust fans, clothes dryers, fireplaces, and other
fuel burning appliances all use the air inside the building. If
the available fresh air is insufficient to meet the demands of
these appliances, problems can result.
The Sundance Vent Free Stove has specific fresh air
requirements. You must determine that these fresh air
requirements will be met within the space where the
appliance will be installed. The following information will
help you insure that adequate fresh air is available for the
heater to function properly.
!
This heater must have fresh air for proper operation. If
not, poor fuel combustion could result. Read the following
instructions to insure proper fresh air for this and other
fuel-burning appliances in your home.
7
WARNING
Monessen • Sundance VF Installation Manual_R1 • 04/17
!
If the area in which the heater may be operated does
not meet the required volume for indoor combustion air,
combustion and ventilation air shall be provided by one
of the methods described in the National Fuel Gas Code,
ANSI Z223.1/NFPA 54, the International Fuel Gas Code
or applicable local codes.
WARNING
3-90-733069