JVC TH-P5B Service Manual page 22

Dvd digital cinema system
Table of Contents

Advertisement

STEP
OPERATION
Press +10 at 10 key of remocon.
6
12
Press STOP key of main unit/remocon.
13
Press OPEN/CLOSE key of main
14
unit/remocon.
Press PLAY key of main unit/remocon.
15
7
Press MENU key of remocon.
Press POWER key of main unit.
*1 Mode toggle by press MENU key.
*2 STEP2-3 and STEP3 are only for DVD-AUDIO or VR correspondence model.
4.3
Key special mode
Mode name
Tuner 9k/10k select
(U*version)
TRAY LOCK
DVD TEST MODE
SYSTEM TEST MODE
AVC ROM-CORE MODE
4.4
Remocon special mode
Mode name
COLD START
FL all on
Preset frequency writeing
Version indication
1-22 (No.MB512<Rev.002>)
BCA READ CHECK
0 : During BCA READ
1 : BCA READ OK
2 : BCA SEEK ERROR
3 : BCA READ ERROR
4 : SPINUP adjustment ERROR
Disc stop, LD-OFF.
Tray open/close.
Disc playback.
Return to STEP2.
Releasr the TEST MODE.
Operation
Press STOP key & PLAY key together
at TUNER AM then 9kHz step.
Press STOP key & PAUSE key together
at TUNER AM then 10kHz step.
Press STOP key & EJECT1 key together
at P.OFF.
At AC off line condition, press
PLAY+POWER together and keep
condition, connect AC.
At AC off line condition, press
PAUSE+POWER key together and keep
condition, connect AC.
At AC off line condition, press
STOP+PAUSE key together and keep
condition, connect AC.
CODE
Operation
B330
2-times input at P.OFF.
B331
Input at P.ON.
B33E
Input at P.ON.
MOVEMENT
9kHz/10kHz step select of TUNER AM band.
DO the TRAY LOCK mode select. Temporaly P.ON operation, select
"LOCKED", "UNLOCKED". (Not done P.ON operation).
Transience (2sec.) indication end, and then return to P.OFF mode.
When press the EJECT key at LOCK mode, at P.OFF condition
tempraly P.ON operation and then transience (2sec.) indication
"LOCKED".
At P.ON condition, transience (2sec.) indication "LOCKED".
"Operation to TEST mode to on of DVD backend.
Operation of internal TEST MODE is refer the TEST mode."
"Set to speaker measurement mode.At source AM, operation the
beat cut by remote controller.Other operation is as same as normal
condition.
Mode release by POWER OFF."
Into the AV compulink rom-core rewrite mode.
Function
"Fix by 2 time input, operation temporaly P.ON and then transience(3sec.)
indication "COLD SET".
Indication end, done the P.OFF mode.
AC to off line, operation the COLD START.B330 : remote controller press
POWER + STOP + 0 key together."
"Rewrite preset frequency, LED on chek(each 300ms), FL all onLED on turn
: STANDBY - ILLUMI - REMOCON<VOL+> - <VOL->Volume control of key
input, keep high-speed mode until POWER OFF.
B331 : Remocon POWER + STOP + 1 key together"
"Indication turn Syscon version - Unit version - Distination, Chip select by
transience(5 sec.).
Syscon version : "SC ## $$" (## : Sys version,$ : Sys ROM-core)
Unit version : "BE %%%% "(%%%% : Unit version)
Distination, Chip select : "$$ %%"($$ : sys distination, %% :
"P3" or "P5" or "P7")
B33E : Press remocon POWER + STOP + 10 key together."
FL (LCD) indication
1 2 3 4 5 6 7 8 9
10
C H E C K
Function
11
12
13

Advertisement

Table of Contents
loading

Table of Contents