Error Code #
36
Thermal error
39
Misc. hardware fault
99
STT Status error
Other
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized
Field Service Facility for technical troubleshooting assistance before you proceed.
Observe all Safety Guidelines detailed throughout this manual
ERROR CODES FOR THE STT
The following is a partial list of possible error codes for the STT
STT
Indicates over temperature. Usually accompanied by Thermal LED. Check fan opera-
tion. Be sure process does not exceed duty cycle limit of the machine.
Unknown glitch has occurred on the fault interrupt circuitry. Sometimes caused by
primary over current fault, or intermittent connections in the thermostat circuit.
Error reported by the STT
Generally caused by misconnection of welding leads (reverse polarity). May also be
caused by loss of input voltage or board failure. Observe diagnostic LED's on the
STT
®
Switch PC Board to determine the exact cause.
A complete list of error codes is available in the Power Wave Manager Utility (avail-
able at www.powerwavesoftware.com).
Error codes that contain three or four digits are defined as fatal errors. These codes
generally indicate internal errors on the STT
input power on the machine does not clear the error, contact the Service
Department.
®