Dcr-Trv230/Trv330) ·············································· - Sony DCR-TRV230 Service Manual

Hide thumbs Also See for DCR-TRV230:
Table of Contents

Advertisement

3. RGB AMP Adjustment (PD-138 board)
(DCR-TRV230/TRV330)
Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 3 of CN5502 (VG)
External trigger: Pin 4 of CN5502
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
A5
Specified Value
A = 3.72 ± 0.05V
Adjusting method:
Order Page Address Data
1
0
01
01
2
D
A5
3
D
A5
4
0
01
00
2H
Pedestal
Fig. 5-1-18.
Procedure
Set the data.
Change the data and set the voltage
(A) between the reversed waveform
pedestal and non-reversed waveform
pedestal to the specified value.
(The data should be "00" to "3F")
Press PAUSE button.
Set the data.
Pedestal
A
4. RGB AMP Adjustment (PD-139 board)
(DCR-TRV530)
Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
Order Page Address Data
1
0
01
2
D
A5
3
D
A5
4
0
01
5
A
Pedestal
5-31
VTR stop
No signal
Pin 3 of CN5502 (VG)
External trigger: Pin 4 of CN5502
(PSIG)
Oscilloscope
D
A5
A = 7.58 ± 0.05V
Procedure
01
Set the data.
Change the data and set the voltage
(A) between the reversed waveform
pedestal and non-reversed waveform
pedestal to the specified value.
(The data should be "00" to "FF")
Press PAUSE button.
00
Set the data.
Perform "Black Limit Adjustment".
Pedestal
2H
Fig. 5-1-19.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-trv330Dcr-trv530

Table of Contents