Sony DCR-TRV230 Service Manual page 188

Hide thumbs Also See for DCR-TRV230:
Table of Contents

Advertisement

7. Overall Noise Level Check
Mode
Recording and playback
Signal
No signal: MIC jack left and right
Measurement Point
AUDIO/VIDEO jack left or right
Measuring Instrument
Audio level meter
Specified Value
Below –45dBs
(IHF-A filter ON, 20kHz LPF ON)
Checking Method:
1)
Connect the left terminal of MIC jack and its ground terminal
with a jumper wire.
2)
Connect the right terminal of MIC jack and its ground terminal
with a jumper wire.
3)
Record the signal.
4)
Playback the recorded section.
5)
Check that the noise level is the specified value.
6)
Remove the jumper wires.
8. Overall Separation Check
Mode
Signal
Measurement Point
Measuring Instrument
Specified Value
< >: Left channel check
[ ] : Right channel check
Checking Method:
1)
Connect the <left> [right] terminal of MIC jack and its ground
terminal with a jumper wire.
2)
Input the 400Hz, –66dBs signal in the MIC jack <right> [left].
3)
Record the signal.
4)
Playback the recorded section.
5)
Check that the signal level of the AUDIO/VIDEO jack <left>
[right] is the specified value.
6)
Remove the jumper wire.
5-57
Recording and playback
No signal: MIC jack <left> [right]
400Hz, –66dBs signal: MIC jack
<right> [left]
AUDIO/VIDEO jack <left> [right]
Audio level meter
Below –40dBs

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-trv330Dcr-trv530