How To Read The Indicators - Yamaha Tio1608-D Owner's Manual

I/o rack
Hide thumbs Also See for Tio1608-D:
Table of Contents

Advertisement

How to read the indicators

You can use the [SYSTEM] and [SYNC] indicators to confirm the unit's status.
The indicators can relay operational status, error status, and warnings.
Error status
If one of the following errors has occurred, the device will not operate. Until the error is resolved, the green SYSTEM indicator
will be turned off, and all indicators for all I/O channels will continue to flash.
In addition, certain errors will cause the red SYSTEM indicator to light or flash.
[SYSTEM] Indicators
Off
Flashes 2 times
Off
Flashes 3 times
Off
Lit
The following errors affect the settings or the hardware. However, the device will still be usable. The green SYSTEM indicator
will light, and all indicators for all I/O channels will work normally.
In addition, certain errors will cause the red SYSTEM indicator to light or flash.
[SYSTEM] Indicators
Lit
Flashing
Lit
Flashes 2 times
Lit
Flashes 3 times
Lit
Lit
Tio1608-D
Owner's Manual
Description
Internal Dante error has occurred.
MAC address setting is damaged and Dante
communication is not possible.
Duplicate UNIT ID was found.
Description
The number of Dante transmit flows
exceeded the limit.
Error occurred when communicating with the
head amp.
Internal memory has been corrupted.
You changed the positions of the device
setting DIP switches, or changed the Dante
settings from Dante Controller. Therefore, the
positions of the device setting DIP switches
do not match the actual Dante settings.
- 16 -
How to read the indicators
Possible Solution
The unit is malfunctioning. Please contact
your nearest Yamaha representative.
Make sure each UNIT ID is only used once
on the Dante network.
Possible Solution
Reduce the number of flows by, for example,
using Dante Controller to change some of the
transmit flows to multicast.
Turn the unit off and then on again. If this does
not resolve the problem, please contact your
nearest Yamaha representative.
If using [RESUME] mode, turn the unit off
and then on again. If this does not resolve
the problem, please contact your nearest
Yamaha epresentative.
If the Device Lock setting was enabled from
Dante Controller, disable the setting, or
check the device setting DIP switch
positions, and set them to accommodate the
current situation.