2. INSTALLATION

2.1 Mounting

E4H Series machines are equipped with a stand-alone frame, which supports the machine. At
least 45 inches (114 cm) of space should be allowed on each end of the membrane element
housings for removal and loading of membrane elements. If 45 inches (114 cm) are not
available, the entire membrane element housing may need to be removed for membrane
element replacement.
 
WARNING!! 
WARNING:
Connect the concentrate line to the RO machine's concentrate outlet. A vacuum breaker must
be installed at the highest point along the concentrate line. This provides an atmospheric
break upstream from where the flow enters the drainage system. For systems which include
multiple RO machines, install check valves along each machine's concentrate line prior to
connecting the lines to a common manifold.
 
A  vacuum  breaker  must  be  installed  at  the  highest  point  along  the 
concentrate line. Failure to do so may cause a vacuum to form within this 
line  after  shutdown.  This  may  in  turn  cause  numerous  problems, 
including  biological  fouling,  water  hammer,  leaks  from  RO  housing  side‐
ports, and the siphoning of treatment chemicals. 
 
 