Heating Mode; Defrosting Condition And Process; Noise Silencing Protection; Operation Condition And Process For Fan Mode - Gree GWH07PA-K3NNA6E Service Manual

Outdoor/indoor units with remote control
Table of Contents

Advertisement

Service Manual

① Operation condition and process for fan mode

In fan mode, the IDU fan motor operates at set speed, while the compressor and the ODU fan motor stop. 4-way valve is de-energized
(4-way valve is not available for cooling only unit). Temperature setting range is 16~30℃ .
② Display: Operation icon, set temperature.
③ Protection function
In fan mode, there are overcurrent protection and blocked protection of IDU fan motor. Please refer to corresponding protection function
under cooling mode for details.
(5) Heating mode(no heating mode is not available for cooling only unit)
① Operation conditioner and process for heating mode
◆ When Tamb. ≤Tset+2℃ , the system starts heating operation. In this case, the 4-way valve is energized. The compressor and the
ODU fan motor operates simultaneously; The IDU fan motor will be started up after delayed for a period of time to make sure the air
conditioner won't blow out cold wind.
◆ When Tamb.≥Tpreset+4℃ , the compressor and the ODU motor stop. The 4-way valve is energized all the time. The IDU fan
motor will blow residual heat after operating at set speed for a period of time consecutively to make sure the inner temperature of air
conditioner won't be too high.
◆ When Tpreset<Tamb.<Tpreset+4℃ , the system will maintain its previous operation status.
In heating mode, 4-way valve is energized. Temperature setting range is 16~30℃ .
② Display: Operation icon, heating icon, set temperature.

③ Defrosting condition and process

For ensusing heating effect, air conditioner will defrost automatically according to defrosting status on outdoor unit. Dual-8 nixie tube
displays H1 during defrosting. (Heating icon is bright for a period time and then OFF for some models)
④ Protection function
◆ Overheating prevention protection
During operation, when controller is detected that Ttube>55℃ , the ODU fan motor stops operation; When Ttube is resumed normally,
the ODU fan motor resumes operation.

◆ Noise silencing protection

When turning off the unit or during mode switchover, the 4-way valve is closed. In order to decrease noise, the 4-way valve will delay
2mins to be closed.
◆ Overcurrent protection ( this protection function is not available for those models whose cooling capacity ≤12000Btu/h)
During operation process, if controller detected that system current exceeds the limit value for 3s consecutively(overcurrent), the
system stops operation. About 3mins later, if overcurrent is released, the system will resume original operation. If overcurrent protection
occurs for 6 times consecutively, and resume operation time won't exceed 6min every time, overcurrent protection information will be
displayed. After turning off the unit, display won't be displayed.
If turn on the unit again, the system will be restated up again. Overcurrent protection information will be eliminated.
Please refer to maintenance part for display information and disposal method for details.
◆ Locked protection to IDU fan motor
During operation of IDU fan motor, if controller detected that the rotation speed of IDU fan motor less than 300/min or stop rotation, the
motor operates abnormally. In order to prevent damage to motor, controller will protect automatically, the system stops operation and
blocked information of IDU fan motor will be displayed. After turning off the unit, display won't be displayed.
If turn on the unit again, the system will be restated up again. Blocked information of IDU fan motor will be eliminated. (For some mod-
els, they can only be restated up after re-energized)
Please refer to maintenance part for display information and disposal method for details.
Technical Information
T
+4
preset
T
+2
preset
T
.
amb
m
i
. n
Compressor
Outdoor unit
Intdoor unit
Set fan speed
min.
Reversing
valve
Stop heating
Original operating status
Start heating
min.
m
i
. n
min.
Set fan speed
37