32Z07617.book 27 ページ 2012年7月31日 火曜日 午後3時21分
NOTE:
• The DC receptacle can be used while the AC power is in use.
If you use both at the same time, do not exceed the maximum AC
power.
Maximum AC power: 1.5 kVA
• Most appliance motors require more than their rated wattage for
startup.
• Make sure the electrical rating of the tool or appliance does not
exceed that of the generator. Never exceed the maximum power
rating of the generator. Power levels between rated and maximum
may be used for no more than 30 minutes.
• Substantial overloading will switch OFF the AC circuit protector
(Except U type). Exceeding the time limit for maximum power
operation or slightly overloading the generator may not switch the AC
circuit protector OFF, but will shorten the service life of the generator.
• Limit operation requiring maximum power to 30 minutes.
Maximum power is: 2.0 kVA
• For continuous operation, do not exceed the rated power.
Rated power is: 1.6 kVA
• In either case, the total power requirements (VA) of all appliances
connected must be considered.