Operating With A Key-Chain Remote - Nemtek AGRI Instruction Manual

Electric fence energizers
Hide thumbs Also See for AGRI:
Table of Contents

Advertisement

AGRI
AGRI Solar
Navigate through the energizer menu using the
To change a setting, press and hold the
value to be altered*.
Alter the value using the
button briefly.
Once you are satisfied with your new settings, present the remote to the energizer again, to
transfer the new settings to the energizer.
A short press of the
Additional information on menu items
Energizer effort or capacity used is useful in determining if your fence condition has changed
since installation. It can also be used to indicate that the energizer is unable to drive the
fence load. To use as a fence condition change indicator, set the WARN AT value above that
of the reported EFFORT value. When the loading on the fence increases and the energizer
starts to work harder, the high intensity warning light will begin to flash and will be seen from
a distance. To use as an energizer maximum capacity reached warning, set the WARN AT
value to 95%. When the high intensity warning light begins to double flash, you will know the
voltage on the fence is about to, or has already, dropped below the set voltage.
V MIN, is the lowest fence voltage recorded since the energizer was last read using a remote.
% MAX, is the maximum energizer effort or capacity used since the energizer was last read
using a remote.
As examples of use for this information, consider the following scenario;
If the fence is being shorted out by faulty insulators during a patch of rain this would be
recorded and reported the next time the remote is presented.
If the fence is being deliberately shorted in order to gain access to your animals at night, then
this would be recorder as a % MAX value of 100% and a low V MIN value.
As this information is reset each time the remote is presented to the energizer, be sure to
remove the remote after the first beep else the recorded values will be lost.
Notes
*Only energizer settings can be altered. Information items such as supply voltage and
energizer effort cannot be altered as they are presented as information only.
button until a flashing cursor appears beneath the
or
buttons and then return to navigate further by pressing the
button, while navigating the menu, will switch the remote off.
15
Operating with a
key-chain remote
or
buttons.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AGRI and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Agri solar

Table of Contents