Pad Replacement
1. Remove media frame from unit side by extracting one screw.
2. Remove and dispose of used media.
3. Install new media pad per instructions
noted here.
NOTE: Proper orientation of the media is
critical to ensure cooling effectiveness.
4. Install the media pad so that the steeper
angle of the flute slopes down toward the
bottom of the media frame.
5. Insert the stems through the four screw
holes in the media frame.
6. Push stems through the media and
fasten media in place with the four
keepers. Take care not to damage the
media.
7. Reinstall media frame onto the body
using one screw.
End of Season Servicing
1. Accomplish Regular Servicing procedures. Ensure unit is fully drained of water.
2. Carefully inspect media to verify media is not crushed, broken and clogged or
heavily encrusted with minerals. If so, dispose and replace media pad.
3. Clean interior with clean water. Wipe down outside with clean damp cloth.
4. Store in safe, dry place. Do not store with water in reservoir.
Trouble shooting :
PROBLEM
Pump is not working
Fan not operating
Unit is not cooling as well
as previously
PROBABLE CAUSE
Unit may be out of water
Pump may be defective
No power supplied.
Insufficient air flow
(input and exhaust.)
Clogged or dirty media
6
45°
15°
REMEDY
Fill reservoir with water and
activate pump.
Replace pump
Verify unit is plugged into a
120V power outlet and
turned on.
Check fuse or breaker.
If connected to GFCI outlet,
check if tripped and reset.
Ensure windows/doors are
open for correct air flow.
Check media pad and wash
or replace as necessary.
Need help?
Do you have a question about the CP35 and is the answer not in the manual?
Questions and answers