Section 2: Actuator Disassembly
August 2015
2.4.13 Remove hex cap screws (7-115) with lockwashers (7-110) from inner end cap
2.4.14 Remove hex nuts (7-105) from hex cap screws (7-100).
2.4.15 Remove hex cap screws (7-100) with lockwashers (7-110) from inner end cap (7-
2.4.16 Remove inner end cap (7-10) off of piston rod (7-40).
NOTE:
The piston rod (7-40) removal as outlined in step 2.4.17 is only required when the piston
rod is being replaced or when the drive module is to be disassembled.
2.4.17 Remove piston rod (7-40) from the drive module.
12
(7-10).
10) and housing (1-10).