Yearly Maintenance (Or Every Two Tons); Clean The Exhaust Duct - Avalon Astoria Pellet Stove Astoria PS Owner's Manual

Avalon pellet stove owner's manual astoria ps
Table of Contents

Advertisement

3 2

Yearly Maintenance (or every two tons)

WARNING:
Disconnect the power cord prior to conducting service.
The following section details extensive maintenance procedures. We strongly suggest these items
be carried out by a trained service technician, possibly by a service agreement set up with your dealer.
Soot and Flyash: Formation and Need for Removal – The products of combustion will
contain small particles of flyash. The flyash will collect in the exhaust venting system and restrict the
flow of the flue gases. Incomplete combustion, such as occurs during startup, shutdown, or incorrect
operation of the room heater will lead to some soot formation which will collect in the exhaust venting
system. The exhaust venting system should be inspected at least once every year to determine if
cleaning is necessary.
Clean the Vertical Exhaust Duct

Clean the Exhaust Duct

(the stove must be cool and
unplugged)
Clean the Convection
Blower
(the stove must be cool and
unplugged)
Travis Industries
Maintenance
(the stove must be cool and unplugged)
Remove both
refractory clips.
The convection
blower inlet can
be vacuumed
out (if needed).
If extensive
cleaning is
needed, it can
be removed for
cleaning.
4050225
Clean the refractory and
the entire area behind it
(both sides).
a
b
Remove these doors to
remove fallen flyash and
soot (see "Bi-Weekly
Open the hopper lid and remove the two
screws holding the side doors in place.
Phillips
Screwdriver
Swing the side panels open.
c
Use a vacuum or bottle
Remove the
brush to remove all
cover plates over
flyash from the exhaust
the exhaust duct
duct (if the gasket is
(both sides)
damaged, replace).
Cover Plate
7/16" Nutdriver
1 0 0 - 0 1 1 5 4
d

Hide quick links: