Measuring
No.
Item
instrument &
Input signals

2.5 INITIALIZE

2.6 ADJUSTMENT OF SSG

1
fsc
Frequency
adjustment
counter
Measuring point (*)
Adjustment parts (-)
Mode
Adjustment level (+)
* TP207 [PRO]
- EVRUSR
[CAT: CLAMP, Byte: 5]
+
U-ver.
3.579545MHz
E-ver.
4.43361875MHz
Adjustment procedure
1) Select either "TK-C400U.cor" for TK-C400U
or "TK-C400E.cor" for TK-C400E/401EG to on
Scenario file define adjustment.
2) Selecting either "NEXT" or "BACK" button
to be initialized the camera data.
All EVR are installed the initial data. (See 2.4.3)
1) Select the "NEXT" button to display "fsc ad-
justment" on the title bar.
2) Adjust the EVRUSR with " " and " " buttons
to obtain the specified level at the measuring
point.
2-5