EMS Signal point Installation Manual

Input/output unit

Advertisement

Quick Links

INPUT/OUTPUT UNIT
INSTALLATION MANUAL

Advertisement

loading

Summary of Contents for EMS Signal point

  • Page 1 INPUT/OUTPUT UNIT INSTALLATION MANUAL...
  • Page 2: Table Of Contents

    Table of Contents Section Page No 1. INTRODUCTION....................3 2. I/O UNIT POSITIONING ..................3 3. INSTALLATION ....................3 4. INPUT/OUTPUT UNIT LOGGING ON PROCEDURE ..........4 5. TESTING THE SYSTEM..................7 TSD012 SIGNALPOINT I/O UNIT, ISSUE 1 – 09/09/13...
  • Page 3: Introduction

    1. Introduction The installation and programming of the 83-5610/MH Radio Input/Output unit used in conjunction with the SignalPoint Control Panel, is detailed in the following instructions. The I/O unit is a monitored input/output device, capable of transmitting VHF alarm signals to the control panel upon activation of its hardwired input. The unit will also receive UHF transmissions from the control panel, which remotely operates the units relay output.
  • Page 4: Input/Output Unit Logging On Procedure

    4. Input/Output Unit Logging on Procedure The process of adding I/O Units to the SignalPoint Control Panel, is largely carried out automatically, by the panel’s own operating system. It is usual practice for each unit to require “logging on” to the system. In such cases, the following action must be taken. Should the system have been received “pre-programmed”, the unit will have been added to the system at the factory and this section will not be required.
  • Page 5 Press the ‘YES’ key to change and the screen will now display: Enter Device (Numbers 1-256) Press the ‘0’ key and the screen will now display: Number> Yes= Finish Time Enter the slot number that you want to add a device to |**Logon Options** (e.g.
  • Page 6 Figure 1 | Slot is :IN USE | Press the ‘YES’ key until the screen displays: >Logon is DISABLED< |\/\/\/\/\/\/\/\/\/\/\| Note: This function must be returned to disabled once the logging on sequence has been completed. 01 FAULT TOT 02 Default Device 125 Press the ‘NO’...
  • Page 7: Testing The System

    The units relay can be activated and de-activated by pressing the control panel’s Sound alarms and Silence Alarms buttons. If after checking these points a problem persists, call EMS Technical Support department on 08712 710804 for assistance.
  • Page 8 Sea Street Herne Bay, The information contained within this literature is Kent CT6 8JZ correct at time of publishing. The EMS Group reserves England the right to change any information regarding Tel: +44 (0) 8712 710804 products as part of its continual development enhancing new technology and reliability.