Brivis CC315IN Installer Manual

Brivis CC315IN Installer Manual

Compact classic ducted

Advertisement

Brivis Compact
Classic Ducted
Gas Heater
Installer's Manual
PLEASE READ THESE INSTRUCTIONS CAREFULLY
BEFORE INSTALLING THIS PRODUCT
i

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CC315IN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Brivis CC315IN

  • Page 1 Brivis Compact Classic Ducted Gas Heater Installer’s Manual PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING THIS PRODUCT...
  • Page 2: Scope

    Scope This Installer's Manual is intended to be used as a guideline for the installation of Brivis Gas Fired Central Heaters. It covers only the installation and commissioning of the heater and the allowable flue configurations. Although recommended return air grilles and allowable duct outlet quantities are specified, it does not cover the actual ducting design required to suit the installation.
  • Page 3: Table Of Contents

    2.5 Changing the Return Air Pop ..................5 2.6 Flue Instructions ......................5 2.6.1 General ........................5 2.6.2 All Compact Classic models ..................5 2.6.3 Brivis Remote Flue Terminal ..................6 2.7 Fan Speed Setting ......................6 2.8 Wiring Diagram ......................6 3.0 Ducting Information ......................7 4.0 Outlet Guide ........................
  • Page 4: General Guidelines

    1.0 General Guidelines Brivis Compact Classic heaters are designed to provide a central source of heat for a ducted central heating system. Brivis Compact Classic heaters should not be installed downstream from an air washer, an evaporative cooler or refrigerative cooling system. Nor are they designed to be installed on a marine craft, houseboat, or any similar environment.
  • Page 5: Electrical Power Supply

    20mm per metre of lateral run • The flue must be terminated outside the building in accordance with AS 5601. This termination can be performed using a Brivis Remote Terminal. Refer to the Fluing instructions, Section 2.6...
  • Page 6: Compact Classic Model Guidelines

    2.0 Compact Classic Model Guidelines 2.1 Heater Dimensions Diagram 1. ø ø Ø100mm View A1-A1 Table 1: Compact Classic unit dimensions Dimension CC315 CC320 CC320XA CC325 CC325XA CC330 CC330XA [mm] øSa øRa...
  • Page 7: Service Clearances

    2.2 Service Clearances Method 1 - In Ceiling & Under Floor 300mm 750mm Diagram 2. Minimum Heat 250 mm Exchanger Cabinet Minimum Cabinet 750mm Heat Service Clearance Minimum Exchanger Cabinet Cabinet Platform Method 2 - In Ceiling & Under Floor Diagram 3.
  • Page 8: Recommended Duct Connection Options

    There are two options available for the return air and one option for the supply air. Please refer to Diagram 4 which highlights the preferred connection options for your unit. Diagram 4. Supply and Return air options Preferred Option Preferred CC315IN CC320IN Option CC325IN CC320IN-XA CC325IN-XA...
  • Page 9: Brivis Remote Flue Terminal

    In specific installations, for example under the floor, it is recommended that a remote terminal be used to terminate a horizontal flue on the outside wall of the building. Please refer to instructions supplied with a Brivis Remote Flue Terminal. Figure below depicts typical Compact Classic underfloor configuration.
  • Page 10: Ducting Information

    3.0 Ducting Information Good duct design and sizing are essential to every Brivis Central Heating system. Use the Brivis "SuperSizeGuide" and technical data within this manual for the best results and follow these guidelines: • Ductwork should be well insulated, airtight and have a minimum insulation rating of R1.O (R1.5 in some areas).
  • Page 11: Outlet Guide

    4.0 Outlet Guide The outlet chart provides recommendations based on using the Brivis "SuperSizeGuide" or a system designed using accepted design principles. These figures also relate to typical size registers and diffusers used on domestic heating systems i.e. 300mm x 100mm floor registers and 150mm round ceiling diffusers, with 150mm ductwork connection.
  • Page 12: Commissioning And Control Settings

    • All these steps must be carried out by a qualified tradesperson • If the heater cannot be adjusted to operate in accordance with these instructions, then contact the Brivis Customer Service Centre (contact details are on the back cover of this manual) 5.1 Commissioning Instructions...
  • Page 13: Setting The Fan Speed

    (for example, a Certificate of Compliance and Certificate of Electrical Safety). Note: Product warranty registration forms can be found online at brivis.com.au or in the owner’s manual. 6.0 Technical Specifications Table 4: Compact Classic Technical Specifications...
  • Page 14 Notes:...
  • Page 15 Notes:...
  • Page 16 © Brivis Climate Systems Pty. Ltd. 2013. All rights reserved. No part of these documents may be used in any way or form without prior written consent from Brivis Climate Systems Pty Ltd. Part Number: B024938 December 2013...

This manual is also suitable for:

Cc320inCc325inCc325in-xaCc320in-xaCc330in-xaCc330in

Table of Contents