General
Information
Thank you for purchasing your
Hydromatic
Basin Mixer Control
®
Panel. To help ensure years of
trouble-free operation, please read
the following manual carefully.
Before Operation:
Read the following in structions
care ful ly.
Reasonable
and safe meth ods should be
practiced. Check local codes and
requirements before installation.
Attention:
This manual contains important
information for the safe use of
this product. Read this manual
completely before using this
product and refer to it often
for con tin ued safe product use.
DO NOT THROW AWAY OR
LOSE THIS MAN U AL. Keep
it in a safe place so that you may
refer to it often.
Unpacking Panel:
Remove
panel
from
When un pack ing unit, check
for concealed damage. Claims
for damage must be made at
the receiving end through the
delivery carrier. Damage cannot
be processed from the factory.

CALIFORNIA PROPOSITION

65 WARNING:
This product and
related
accessories
chemicals known to the State of
California to cause cancer, birth
defects or other reproductive
harm.
2
Power
Supply
WARNING: Do not attempt to
wire this control box unless you
have a good working knowledge
of electricity and are familiar
with the state and local codes. If
you are in doubt about anything,
contact a qualified electrician.
Do not attempt to operate this
care
unit on any other voltage or
power distribution other than
for which it was originally
designed (check nameplate).
Failure to comply with this
will result in the immediate
cancellation of all warranties
and claims.
It is advisable to put the panel
on its own circuit using a circuit
breaker adequately sized to protect
the mixer. Check state and local
codes for the correct wire size and
circuit protection to use. The wire
should be sized large enough to
handle the full load current of the
mixer you are operating and any
carton.
voltage drop that might occur due
to long service runs.
Run power supply lines to the
control box and secure (knockouts
are not supplied in this box).
Select a convenient location on
the bottom to enter the box with
the power supply. Cut a hole with
a chassis punch. Caution should
be taken not to get metal chips
in the components while cutting
contain
hole. After the hole is cut, any
metal particles must be removed
from the box. Failure to do so may
result in premature component
failure.
Connect incoming power to the
terminal blocks per the included
schematic and all necessary
ground wires to the ground lug at
the bottom right of the box. The
ground lug should be fastened to
a good driven earth ground by
one of the methods described in
the National Electric Code. NEC
does not permit using ground
as a current-carrying conductor,
therefore a neutral must be
provided for 115 volt 1 phase, 208
volt 1 phase, 230 volt 1 phase, or
208 volt 3 phase systems.
WARNING: Before handling
these mixers and controls,
always disconnect the power
first. Do not smoke or use
sparkable electrical devices or
flames in a septic (gaseous) or
possible septic sump.
Electrical Connections:
The contractor must conform
to the latest requirements of the
National Electrical Code. All
conduit and ca bles shall be in
accordance with NEC Code
NFPA #70. To maintain UL and
CSA ENCL rating, use the same
type UL and CSA weatherproof
con duit hubs when connecting to
this en clo sure. Prior to conducting
any in stal la tion, repair or service
with re gard to the control panel,
refer to the schematic appropriate
for that panel. The schematic will
provide guidance with regard to
the terminal block con nec tions.
CAUTION:
A
nonmetallic
enclosure does not provide
grounding conduit con nec tions.
Use grounding bush ing and
jumper wires.
Make the Following
Electrical Con nec tions:
a. Connect the mixer leads to the
control panel.
b. Connect the mixer heat sensor
and seal failure leads (if