Product specification
Table 3:
Pin description for LQFP32
[1]
Symbol
Pin
Type
[3]
OC5/GOC
7
AI/I
DM4
8
AI/O
DP4
9
AI/O
SP/BP
10
I
HUBGL
11
O
[3]
PSW3/GL3
12
O
[3]
PSW4/GL4
13
O
PSW5/GL5/
14
O
[3]
GPSW
XTAL1
15
I
XTAL2
16
O
[2]
RESET
17
I
OPTION/SCL
18
I/O
INDV/SDA
19
I/O
DM5
20
AI/O
DP5
21
AI/O
DM1
22
AI/O
DP1
23
AI/O
DM0
24
AI/O
DP0
25
AI/O
Rev. 03 — 29 March 2000
...continued
Description
modes 5, 7: overcurrent sense input for downstream port 5
[5]
(analog
)
modes 0, 1, 3: global overcurrent sense input (analog
downstream port 4 D connection (analog)
downstream port 4 D connection (analog)
selects power mode:
self-powered: connect to V
this mode for hybrid-powered operation
bus-powered: connect to GND; disable downstream port 5 to
meet supply current requirements
hub GoodLink LED indicator output (open-drain, 6 mA);
to connect an LED use a 330
connect to V
via a 10 k resistor
CC
modes 4 to 6: power switch control output for downstream
port 3 (open-drain, 6 mA)
modes 0 to 3, 7: GoodLink LED indicator output for
downstream port 3 (open-drain, 6 mA); to connect an LED
use a 330
series resistor
modes 4 to 6: power switch control output for downstream
port 4 (open-drain, 6 mA)
modes 0 to 3, 7: GoodLink LED indicator output for
downstream port 4 (open-drain, 6 mA); to connect an LED
use a 330
series resistor
mode 5: power switch control output for downstream port 5
(open-drain, 6 mA)
modes 3, 7: GoodLink LED indicator output for downstream
port 5 (open-drain, 6 mA); to connect an LED use a 330
series resistor
modes 0 to 2: gang mode power switch control output
(open-drain, 6 mA)
crystal oscillator input (6 MHz)
crystal oscillator output (6 MHz)
reset input (Schmitt trigger); a LOW level produces an
asynchronous reset; connect to V
(internal POR circuit)
mode selection input; also functions as I
(open-drain, 6 mA)
selects individual (HIGH) or global (LOW) power switching
and overcurrent detection; also functions as bidirectional
2
I
C-bus data line (open-drain, 6 mA)
downstream port 5 D connection (analog)
downstream port 5 D connection (analog)
downstream port 1 D connection (analog)
downstream port 1 D connection (analog)
upstream port D connection (analog)
upstream port D connection (analog)
ISP1122
USB stand-alone hub