Philips Semiconductors
Table 8:
Hub specific requests
Request name
Status
Get Hub Status
Get Port Status
Unsupported
Get Bus Status
Clear Hub Feature
(C_OVER_CURRENT)
Set Hub Descriptor
Set Hub Feature
(C_LOCAL_POWER)
Set Hub Feature
(C_OVER_CURRENT)
USB Specification Rev. 1.0 uses 00H, USB Specification Rev. 1.1 specifies 29H.
[1]
[2]
Returned value in bytes.
[3]
Feature selector value, see
[4]
Downstream port identifier: 1 to N with N = number of enabled ports (2 to 5).
9397 750 07002
Product specification
...continued
bmRequestType
bRequest
byte 0 [7:0]
byte 1
(Bin)
(Hex)
1010 0000
00
1010 0011
00
1010 0011
02
X010 0000
01
0010 0000
07
X010 0000
03
X010 0000
03
Table
9.
Table 9:
Port feature selectors
Feature selector name
PORT_CONNECTION
PORT_ENABLE
PORT_SUSPEND
PORT_OVERCURRENT
PORT_RESET
PORT_POWER
PORT_LOW_SPEED
C_PORT_CONNECTION
C_PORT_ENABLE
C_PORT_SUSPEND
C_PORT_OVERCURRENT
C_PORT_RESET
Rev. 03 — 29 March 2000
wValue
wIndex
byte 2, 3
byte 4, 5
(Hex)
(Hex)
00, 00
00, 00
[4]
00, 00
port
, 00
[4]
00, 00
port
, 00
01, 00
00, 00
XX, XX
00, 00
00, 00
00, 00
01, 00
00, 00
Value (Hex)
Set feature
00
not used
01
not used
02
suspends a port
03
not used
04
resets and enables a
port
08
powers on a port
09
not used
10
not used
11
not used
12
not used
13
not used
14
not used
ISP1122
USB stand-alone hub
wLength
Data
byte 6, 7
(Hex)
04, 00
hub status and
status change
field
04, 00
port status
01, 00
STALL
00, 00
STALL
3E, 00
STALL
00, 00
STALL
00, 00
STALL
Clear feature
not used
disables a port
resumes a port
not used
not used
powers off a port
not used
clears port connection
change bit
clears port enable
change bit
clears port suspend
change bit
clears port overcurrent
change bit
clears port reset
change bit
© Philips Electronics N.V. 2000. All rights reserved.