Olivetti PG L2140 Service Manual page 50

Hide thumbs Also See for PG L2140:
Table of Contents

Advertisement

 
Service items
Maintenance
Counter reset for the maintenance kit
Description
The "Install MK" message means that maintenance kit should be replaced at fixed pages
of printing. The interval counter must be manually reset using this service item.
Maintenance kit MK-3102 (for 120 V ) (40 ppm)
Maintenance kit MK-3132 (for 120 V ) (50/45 ppm)
Maintenance kit MK-3100 (for 230 V ) (40 ppm)
Maintenance kit MK-3130 (for 230 V ) (50/45 ppm)
Maintenance kit includes the following units:
Drum unit
Developer unit
Transfer roller assembly
Fuser unit
Paper feed roller assembly
Retard roller assembly
Purpose
To reset the life counter for maintenance kit.
Method
Drum unit (see page 1-5-15)
Developer unit (see page 1-5-13)
Transfer roller assembly (see page 1-5-16)
Fuser unit (see page 1-5-19)
Paper feed roller assembly (see page 1-5-8)
Retard roller assembly (see page 1-5-8)
Method
1. Enter the Service Setting menu.
2. Select [Maintenance] using the cursor up/down keys.
3. Press the OK key.
4. Select the [YES] using the left select key.
[Completed] is displayed.
The counter for each component is reset immediately.
Note:
Occurrences of resetting the maintenance kits are recorded on the service status page
or event log in number of pages at which the maintenance kit was replaced (see page 1-
3-2, page 1-3-18 ). This may be used to determine the possibility that the counter was
errorneously or unintentionally reset.
Y 114940 - 1
Description
1-3-12
Service Manual
:300,000 images
:500,000 images
:300,000 images
:500,000 images