Drive Migration - Lenovo ServeRAID M1115 User Manual

Sas/sata
Hide thumbs Also See for ServeRAID M1115:
Table of Contents

Advertisement

1.8.8

Drive Migration

1-14
Note:
If you move a drive that is being rebuilt, the rebuild
operation will restart, not resume.
Follow these steps to use drive roaming:
Step 1.
Turn off the power to the server and all physical disks,
enclosures, and system components. Disconnect the power
cords from the system.
Step 2.
Open the host system by following the instructions in the host
system technical documentation.
Step 3.
Move the drives to different positions on the backplane to
change the targets.
Step 4.
Determine the SAS target requirements.
Step 5.
Perform a safety check.
a. Make sure that the drives are inserted correctly.
b. Close the cabinet of the host system.
Step 6.
Reconnect the power cords to the system.
Step 7.
Turn on the power to the system.
The controller then detects the RAID configuration from the
configuration data on the drives.
Drive migration is the transfer of a set of drives in an existing
configuration from one controller to another. The drives must remain on
the same channel and must be reinstalled in the same order as in the
original configuration. The controller to which you migrate the drives
cannot have an existing configuration.
Note:
Only complete configurations can be migrated; individual
virtual disks cannot be migrated.
Note:
Drive roaming and drive migration cannot be supported at
the same time.
Follow these steps to migrate drives: