Coleman PxXU-V series Installation Instructions Manual page 6

Two-stage ultra high-efficiency gas-fired variable speed furnaces
Table of Contents

Advertisement

B
A
FRONT
B
VENT CONNECTION
(VENT SIZE
20
POWER
WIRING
7/8 K.O.
1-7/8
E
F
FRONT
TOP IMAGE
RETURN END
FIGURE 2 :
Dimensions - Downflow/Horizontal Models
Table 2: RATINGS & PHYSICAL / ELECTRICAL DATA - DOWNFLOW/HORIZONTAL MODELS
P*XD-V/G9V-DH
CABINET
INPU
OUTPUT
WIDTH
NOM.
MBH
MBH
(INCHES)
CFM
H/L
H/L
80/52
75/48
1200
17-1/2
120/78 112/72 2000
24-1/2
1.
AFUE numbers are determined in accordance with DOE test procedures
2.
Wire size and overcurrent protection must comply with the National Electrical Code (NFPA-70-latest edition).
For altitudes above 2,000 ft., reduce capacity 4% for each 1,000 ft. above sea level. Refer to Form 035-14460-000.
Wire size based on copper conductors, 60°C, 3% voltage drop.
Continuous return air temperature must not be below 55°F.
Table 3: UNIT CLEARANCES TO COMBUSTIBLES
APPLICATION
TOP
FRONT
UPFLOW
1
3
DOWNFLOW
1
3
HORIZONTAL
1
3
1.
Special floor base or air conditioning coil required for use on combustible floor.
2.
Minimum of 8" clearance required to install condensate removal system.
3.
Line contact only permitted between lines formed by the intersection of the rear panel and side panel (top in horizontal position) of
the furnace jacket and building joists, studs or framing.
6
20
3/4
T'STAT WIRING
7/8 K.O.
CONDENSATE
DRAIN ACCESS
3-1/4 x 3
5-1/4
AIR INTAKE
45
3-5/8 x 3-5/8
1-1/4
G
(
CONN. SIZE/
PIPE SIZE)
GAS INLET
1-1/4 x 2-1/2
28-1/2
LEFT SIDE
A
19-1/4
C
5-3/8
H
FRONT
BOTTOM IMAGE
RETURN END
LOW
HIGH
MAX.
FIRE
FIRE
OUTLET
1
AFUE
TEMP.
TEMP.
AIR
RISE °F
RISE °F
TEMP. °F
92.0
35-65
35-65
165
92.0
40-70
40-70
170
LEFT
RIGHT
REAR
SIDE
SIDE
UPFLOW MODELS (P*XU-V / G9V-UP)
0
0
0
DOWNFLOW / HORIZONTAL MODELS (P*XD-V / G9V-DH)
0
0
0
+
0
0
0
D
VENT CONNECTION
1-3/4
35
16-3/4
18-1/2
3-3/4
7-1/2
6-1/4
2-3/4
1-3/8
MODELS
A
P*XD-V / G9V-DH
80/75/1200/B
17-1/2
16-1/4
120/112/2000/D
24-1/2
23-1/4
8
1. VENT PIPE MUST BE INCREASED TO 3" ON THIS MODEL.
ALL DIMENSION ARE IN INCHES, AND ARE APPROXIMATE.
BLOWER
TOTAL
UNIT
HP AMPS
SIZE
AMPS
1/2
1.7
11 x 8
12.0
1
4.4 11 x 10 14.5
FLUE FLOOR/BOTTOM
0
COMBUSTIBLE
1
0
COMBUSTIBLE
2
0
COMBUSTIBLE
035-17468-001 Rev. A (801)
CONDENSATE
DRAIN ACCESS
3-1/4 x 3
3-3/4
AIR INTAKE
3-5/8 x 3-5/8
G
(
CONN. SIZE/
PIPE SIZE)
1-1/4
ALT. GAS INLET
4-1/8
1-1/4 x 2-1/2
RIGHT SIDE
B
C
D
E
F
14-3/4
2
6-5/8
2-1/4
1
21-3/4
10-1/8
2-1/4
2 (3)
MAX.
MIN WIRE SIZE
OVER-CURRENT
(AWG) @ 75 FT.
2
2
PROTECT
ONE WAY
20
14
20
12
CLOSET
ALCOVE
ATTIC
YES
YES
YES
YES
YES
YES
NO
YES
YES
Unitary Products Group
G
2
3
OPERATING
WT. (LBS)
128
184
LINE
CONTACT
NO
NO
3
YES

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pxxu-g9v-up seriesPxxd-g9v-dh seriesPxxd-v series

Table of Contents