M2M C350 pro Technical Manual page 13

Table of Contents

Advertisement

Technical Manual 1.02, C350 Professional
Wakeup (ignition) input
The DIN5 / Wakeup (ignition) input is a special input as it also functions as the wakeup
input. If the input is activated with a logical high or low (Wait For Event mode only) when
the C350 pro is in low power mode it will wakeup the unit. A power apply will also wake the
unit up if it is in power-down mode or in Wait For Event mode with power Apply and/or
ignition selected for wakeup. The input is de-bounced with a period between 1-2 ms when
used as a digital input. So any logical level applied to this input must be greater than 2 ms
to be valid.
The power management allows the possibility to configure a wakeup on one or more
digital inputs with individually configured falling- or rising edge detection. Please consult
the M2M Control IDE on-line help for more information.
Digital input pins.
Pin
Name
40
DIN1 / S0IN1
41
DIN2 / S0IN2
42
DIN3 / S0IN3
43
DIN4 / S0IN4
44
DIN5 / WAKEUP
45
DIN6
46
DIN7
47
DIN8
48
SGND
49
SGND
For placement and configuration of the hardware jumpers inside the unit, please refer to
the unit configuration guide in Appendix A.
M 2 M C o n t r o l
by Infranet Technologies GmbH
Tempowerkring 2
21079 Hamburg
Germany
Description
Digital input 1
S0 input 1
Digital input 2
S0 input 2
Digital input 3
S0 input 3
Digital input 4
S0 input 4
Digital input 5
Wakeup (ignition) input
Digital input 6
Digital input 7
Digital input 8
Signal ground
Signal ground
Jumper Setting
JP8 position 1-2 (default)
JP8 position 2-3
JP9 position 1-2 (default)
JP9 position 2-3
JP10 position 1-2 (default)
JP10 position 2-3
JP11 position 1-2 (default)
JP11 position 2-3
Page 13 of 38
Ph: +49.40.69647-260
Fax: +49.40.69647-259
Email:
info@m2mcontrol.de
Web: www.m2mcontrol.de