Sharp SJ-48G-GY Service Manual page 7

Hide thumbs Also See for SJ-48G-GY:
Table of Contents

Advertisement

DESTINATION: H
Items
SJ-48G, SJ-D48G
Source
200/220V 50Hz
Climate class
ST
Thermostat
Type: MM1-8025 ON: –17±5˚C OFF: –22±1.5˚C(at normal notch)
Damper thermostat
Type: MM1-6129
Baffle opened 1.5˚C(at normal notch)
Baffle closed –3±1.5˚C
Timer
Type: TMDF904FD2, Integration type
Cycle 10hours 50 min., Working time about 4min. 20sec. 50Hz
Fuse ass'y
Thermo. fuse Type: SF70E 250V 10A Working temp. 70±2˚C
Defrost thermostat
Type: US602S 250V 8A OPEN 10±3˚C CLOSE 1±3˚C
Door switch
3 terminals push-button 250V 0.25A
Lamp socket
250V 1A E-12(HARD PLASTIC BODY TYPE)
Lamp
240V 10W E-12
Fan motor
Type: MH15SAF-TJA7 200/240V 50Hz 0.8W
Compressor
Type: GL-99BL
200/220V 50Hz, 220V 60Hz(OIL COOLING)
Cooling capacity 244W/279W
Main coil 6.68Ω
Aux. coil 9.30Ω ( at 20˚C)
Terminal
Starting relay
PTC/UH-3003 14Ω 350V
Overload relay(Protector) 4TM306NFBYY OFF 120˚C ON 61˚C
Running capacitor
6µF / 400V
Defrost heater
200V 136W / 220V 165W
or MTG4A50072 250V 10A Working temp. 72±2˚C
Common
Aux. coil
Main coil
SJ-51G, SJ-D51G, SJ-55G, SJ-D55G
294Ω
7
SJ-48G/D48G
SJ-51G/D51G
SJ-55G/D55G