Items
Source
Climate class
Thermostat
Damper thermostat
Timer
Fuse ass'y
Defrost thermostat
Door switch
Lamp socket
Lamp
Fan motor
Compressor
Starting relay
Overload relay(Protector)
Running capacitor
Defrost heater

LIST OF ELECTRICAL PARTS

SJ-48G, SJ-D48G
220/230/240V 50Hz
T, ST
Type: MM1-8025 ON: –17±5˚C OFF: –22±1.5˚C(at normal notch)
Type: MM1-6129
Baffle opened 1.5˚C(at normal notch)
Baffle closed –3±1.5˚C
Type: TMDF904FD2, Integration type
Cycle 10hours 50 min., Working time about 4min. 20sec. 50Hz
Thermo. fuse Type: SF70E 250V 10A Working temp. 70±2˚C
or MTG4A50072 250V 10A Working temp. 72±2˚C
Type: US602S 250V 8A OPEN 10±3˚C CLOSE 1±3˚C
3 terminals push-button 250V 0.25A
250V 1A E-12(HARD PLASTIC BODY TYPE)
240V 10W E-12
Type: MH15SAF-TJA7 200/240V 50Hz
Type: GL-90BH
50Hz(OIL COOLING)
Cooling capacity 223W
Main coil 8.8Ω
Aux. coil 17.7Ω ( at 20˚C)
Terminal
Common
Aux. coil
Main coil
PTC/UH-3003 14Ω 350V
4TM276NFBYY OFF 120˚C ON 61˚C
6µF / 400V
220V 137.1W / 230V 150W / 240V 164.9W 353Ω
SJ-51G, SJ-D51G, SJ-55G, SJ-D55G
Type: GL-99BH
50Hz(OIL COOLING)
Cooling capacity 244W
Main coil 8.5Ω
Aux. coil 15Ω ( at 20˚C)
Terminal
Common
Aux. coil
4TM308NFBYY OFF 120˚C ON 61˚C
6
Main coil