Manual Draining Of The Water Heater; Running A Low Volume Of Water Through The Water Heater To Prevent Freezing; When The Water Heater Or External Piping Has Frozen - Giant Factories ANSI Z21.10.3 Owner's Manual

Direct vent tankless water heaters
Table of Contents

Advertisement

SYSTEM MAINTENANCE

Manual draining of the water heater

To avoid burns, wait until the equipment cools down before
draining the water. The water in the appliance will remain hot
after it is turned off.
AVERTISSEMENT
If the water heater is not going to be used during a period of pos-
sible freezing weather, it is recommended that the water inside the
water heater be drained.
ATTENTION
To manually drain the water:
1) Shut off cold water supply and gas supply.
2) Turn off the temperature controller.
3) Disconnect the power to the water heater.
4) Place a container to catch the water. Open hot water tap or
open hot water drain plug at the hot water outlet.
5) Remove water filter to drain the cold water.
6) Unscrew the water drain plug from the drain line next to the
hot water outlet.
7) Remove the condensate trap drain plug and allow draining.
To resume normal operation:
1) Confirm that all water drain plugs are removed, that the gas
supply is turned off, and that all taps are closed.
2) Insert the condensate trap drain plug.
ON!
COLD
3) Screw in the water drain plugs.
4) Screw in the water filter in the cold water inlet.
0,1 gallon / minute
5) Open the cold water supply.
6) Open a tap and confirm that water flows, and then close.
ou environ 0,2 pouce
7) Turn on the power.
(5 mm) d'épaisseur
HOT
8) After confirming that the temperature controller is off, turn on
the gas supply.
9) Turn on the temperature controller.
CAUTION
WARNING
DANGER
Running a low volume of water through the water heater to
prevent freezing
If the temperature exceeds the ability of the water heater to freeze
protect itself, or if power is lost, the following steps may prevent
the water heater and external piping from freezing. (Units con-
nected with EZ Connect (2-unit link) should be drained to prevent
freezing if not in use.)
1) Turn the water heater off.
2) Close the gas supply valve.
3) Turn on a hot water tap to flow water about 0.1 gal/min or
where the stream is about 0.2 inches (5 mm) thick.

When the water heater or external piping has frozen

1) Do not operate the water heater if it or the external piping is
frozen.
2) Close the gas and water valves and turn off the power.
3) Wait until the water thaws. Check by opening the water supply
valve.
4) Check the water heater and the piping for leaks.
Figure 46
ON!
COLD
HOT
48 48
0.1 gal/min or
about 0.2 inch
thick

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ugtc-152nCsa 4.3Ugtc-152pUgtc-199nUgtc-199p