TWIN PIPE VENTING GUIDE
Installation:
1) Once location is determined, cut two (2) appropriately sized
holes in the wall to accommodate the pipe. (Reference the
following Low Profile Termination Kit Dimensions table)
Vers l'entrée d'air
2) Slide intake and exhaust pipes through the holes. Secure (us-
du chauffe-eau
ing solvent cement) both pipes to the base of the vent termi-
nation kit. (Be sure to follow guidelines for solvent cementing
De la conduite
as described in the System 636 Installation Guide)
d'échappement
du chauffe-eau
3) Use the supplied screws and anchors to secure the base to
the wall. (a drilled 3/16'' (4.8 mm) hole, 1-3/16'' (4.8 mm)
Orientation
deep will be needed for the anchors.) Use the base as a tem-
plate to locate the anchor hole.
Terminaison
4) Using the supplied screws, secure the Cap to the Base.
d'entrée
d'air /
5) Upon securing the vent termination and pipes, seal the wall
échappement
penetrations (from the interior) using a PVC compatible seal-
ant material.
N O T I C E
All exhaust vents and air inlets must terminate at the same height
to avoid substantial property damage, personal injury, or death.
Conduite
d'entrée
Low Profile Termination Kits-Dimensions
d'air
Item #
Description
Conduite
3'' (7.6 cm)
d'échappement
196985
Flush Mount
Vent Kit
4'' (10.2 cm)
196986
Flush Mount
Vent Kit

Twin Pipe (PVC/CPVC) Terminations

Évent
PVC/CPVC Sidewall (Tee and Snorkel) Terminations:
Locate the vent and intake air termination using the following
guidelines:
1) The total length of the vent or intake air piping must not ex-
ceed the limits given in Tables 11-14. The equivalent length
for 90° elbows and termination associated with the respective
vent and intake air piping arrangement MUST be subtracted
from total length listed in Tables 11-14.
2) Specific to Side Wall Tee Termination, the vent and intake air
piping must terminate at the outside surface of the outer wall,
minimum one (1) inch (2.5 cm) between wall, tee, and elbow
socket ends (see Figure 24).
3) Termination must be installed twelve (12) inches (30.5 cm),
above the highest anticipated snow level (see Figures 25 & 26).
Terminaison d'entrée
4) Refer to Table 3 this document for recommendation on vent/
d'air / échappement
combustion air intake terminal position.
NOTE: If the vent is terminated on a sidewall which is subject
to high winds it is recommended to terminate the vent using a
tee. A tee provides the best protection against wind.
5) The intake air pipe must terminate using a 90° elbow directed
away from the vent termination. Both vent and air intake pipe
terminations must be installed twelve (12) inches (30.5 cm)
minimum above grade or highest anticipated snow level and
as shown in Figures 25 and 26.
12" (30,5 cm) min
qui surplombe
12" (30,5 cm) min
Niveau
de neige
Pipe Outside
Hole Spacing
Base d'évent
Diameter
(Ctr to Ctr)
Capuchon d'évent
3.5'' (8.9 cm)
5.6'' (14.2 cm)
4.5'' (11.4 cm)
5.6'' (14.2 cm)
12" (30,5 cm) min entre l'entrée
d'air et la sortie d'air adjacente
Air
Figure 23: Kit Contents
To Water Heater Intake
Air Connection
From Water Heater
Vent Pipe Connection
Orientations
Vent / Air
Termination
Air Piping
Vent Piping
Vent
Termination
Table 16:
Qty
1
1
8
4
24
12'' (30.5 cm)
min
to
overhang
12'' (30.5 cm) min
Grade or
Snow Line
Vent Base
Vent Cap
12'' (30.5 cm) Min Between
of Air Inlet and Adjacent
Vent Outlet
Air
Vent / Air
Item Description
Base (Two holes)
Cap (One Hole)
Stainless Steel Screws
Plastic Anchors