Airwell Flo 9 INV Instruction Manual
Airwell Flo 9 INV Instruction Manual

Airwell Flo 9 INV Instruction Manual

Range inverter

Advertisement

INVERTER
Range
Wall units Flo inv
Floor/ceiling SX inv
Cassettes K inv
Flo 9 INV
Flo 12 INV
SX 9 INV
SX 12 INV
K 9 INV
K 12 INV
Technical instructions manual
TM-
TM-
GINV
GINV
GINV- - - - - A A A A A -1GB
-1GB
-1GB
TM-
TM-
TM- GINV
GINV
-1GB
-1GB
Cancels and replaces :
Cooling capacity (kW)
Heating capacity (kW)
2.56 (1.3 - 3)
3.05 (1.03 - 4)
3.4 (1.38 - 3.9)
4.25 (1.23 - 4.78)
2.5 (1.2 - 3.1)
3 (1.3 - 3.65)
3.23 (1.27 - 4.08)
3.5 (1.2 - 4.55)
2.5 (1.2 - 3.1)
2.8 (1.3 - 3.65)
3.2 (1.27 - 4.02)
3.95 (1.2 - 4.55)
INDIVIDUAL COMFORT RANGE

Advertisement

Table of Contents
loading

Summary of Contents for Airwell Flo 9 INV

  • Page 1 Range Wall units Flo inv Floor/ceiling SX inv Cassettes K inv Cooling capacity (kW) Heating capacity (kW) Flo 9 INV 2.56 (1.3 - 3) 3.05 (1.03 - 4) Flo 12 INV 3.4 (1.38 - 3.9) 4.25 (1.23 - 4.78) SX 9 INV 2.5 (1.2 - 3.1)
  • Page 2: Table Of Contents

    CONTENTS PRESENTATION ................3 TECHNICAL SPECIFICATIONS ............7 COOLING CAPACITY ............... 8 HEATING CAPACITY ................. 14 DIMENSIONS • outdoor unit GC ................20 • indoor unit FLO ................21 • indoor unit SX ................22 • indoor unit K ................. 23 INSTALLATION .................
  • Page 3: Presentation

    PRESENTATION The range of INVERTER Heatpump splits, compatible with indoor units: These appliance have been optimized to operate with the R-407C coolant which contains no chlorine and has no wall units effect on the ozone layer. Flo inv floor/ceiling units SX inv colorado cassette K inv...
  • Page 4 The air we breathe is electrically charged, with both positive and negative ions. In closed and urban environments, the concentration of negative ions in the atmosphere is reduced. The ionizer Airwell re-establishes the balance of negative ions in our environment for optimal living comfort.
  • Page 5 PRESENTATION 2.2 Floor/ceiling unit SX inv Having reduced dimensions (only 190 mm deep), and being aesthetically pleasing, it can be very easily installed in any residential, tertiary or industrial location. Supplied as standard for both wall and ceiling installation, without any on site modifications.
  • Page 6 Each unit is supplied with general wiring and connection diagrams and specific installation and operation instructions. the recommendations when Each accessory (or kit) is accompanied by technical specifications for fitting and carrying out any work adjustment as required. You can find all these elements on Internet site : http://www.airwell.com...
  • Page 7: Technical Specifications

    TECHNICAL FLO inv SX inv K inv Models SPECIFICATIONS Power supply ~230 V - 50 Hz • • • • • • 2.55 2.58 Nominal cooling capacity (1.28-3.03) (1.40-4.16) (1.35-3) (1.30-4.20) (1.30-3) (1.30-3.90) Power input in cool 0.88 0.89 1.23 1.17 1.47 3.15...
  • Page 8: Cooling Capacity

    COOLING CAPACITY wall unit Flo 9 inv Outdoor DB temperature Indoor WB 19° Indoor WB 21° Indoor WB 23° Outdoor DB temperature Indoor WB 19° Indoor WB 21° Indoor WB 23°...
  • Page 9 COOLING CAPACITY wall unit Flo 12 inv Outdoor DB temperature Indoor WB 19° Indoor WB 21° Indoor WB 23° Outdoor DB temperature Indoor WB 19° Indoor WB 21° Indoor WB 23°...
  • Page 10 COOLING CAPACITY 3500 3400 3300 3200 3100 3000 2900 2800 2700 2600 2500 2400 2300 2200 2100 floor/ceiling 2000 SX 9 inv Outdoor DB temperature Indoor WB 19° Indoor WB 21° Indoor WB 23° 1500 1400 1300 1200 1100 1000 Outdoor DB temperature Indoor WB 19°...
  • Page 11: Indoor Wb

    COOLING CAPACITY 4500 4400 4300 4200 4100 4000 3900 3800 3700 3600 3500 3400 3300 3200 3100 3000 floor/ceiling SX 12 inv Outdoor DB temperature Indoor WB 19° Indoor WB 21° Indoor WB 23° 1700 1600 1500 1400 1300 1200 1100 1000 Outdoor DB temperature...
  • Page 12: Indoor Wb

    COOLING CAPACITY 3500 3400 3300 3200 3100 3000 2900 2800 2700 2600 2500 colorado cassette 2400 2300 K 9 inv 2200 2100 2000 Outdoor DB temperature Indoor WB 19° Indoor WB 21° Indoor WB 23° 1500 1400 1300 1200 1100 1000 Outdoor DB temperature Indoor WB 19°...
  • Page 13: Indoor Wb

    COOLING CAPACITY 4400 4300 4200 4100 4000 3900 3800 3700 3600 3500 3400 3300 3200 colorado cassette 3100 K 12 inv 3000 2900 Outdoor DB temperature Indoor WB 19° Indoor WB 21° Indoor WB 23° 1700 1600 1500 1400 1300 1200 1100 1000...
  • Page 14: Heating Capacity

    HEATING CAPACITY wall unit Flo 9 inv Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25° Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25°...
  • Page 15 HEATING CAPACITY wall unit Flo 12 inv Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25° Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25°...
  • Page 16 HEATING CAPACITY floor/ceiling SX 9 inv Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25° Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25°...
  • Page 17 HEATING CAPACITY floor/ceiling Outdoor WB temperature SX 12 inv Indoor DB 15° Indoor DB 20° Indoor DB 25° Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25°...
  • Page 18 HEATING CAPACITY colorado cassette K 9 inv Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25° Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25°...
  • Page 19 HEATING CAPACITY colorado cassette K 12 inv Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25° Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25°...
  • Page 20: Dimensions

    DIMENSIONS Dimensions in mm side view front viex condensing unit GC 9 inv GC 12 inv Clearances 800 mm 150 mm 400 mm 100 mm 500 mm INTAKE top view DISCHARGE...
  • Page 21: Indoor Unit Flo

    DIMENSIONS Dimensions in mm side view front view wall units Flo 9 inv Flo 12 inv INTAKE DISCHARGE Clearances Mounting template yo be used for location of indoor 100 mm unit on the wall ceiling 50 mm indoor unit outline...
  • Page 22: Indoor Unit Sx

    DIMENSIONS Dimensions in mm front view side view floor/ceiling SX 9 inv SX 12 inv Clearances 900 mm 200 mm 80 mm 50 mm top view...
  • Page 23: Indoor Unit K

    DIMENSIONS Dimensions in mm colorado cassette K 9 inv K 12 inv DESCRIPTION T bar (suspended ceiling) Suspended ceiling Evaporator Air intake grille Electrical connections Condensates drainage «GAS» valve «LIQUID» valve Fresh air intake Orifice for ducted air distribution into adjacent room...
  • Page 24: Installation

    INSTALLATION indoor unit 1. Choose a location which will provide good air circulation.ensure that no objects or furnishings prevent air circulation. 2. Do not install the unit near a heat source or where it will be exposed to direct sunlight. 3.
  • Page 25: Connections

    CONNECTIONS The pipe and electrical wiring connections to be made between the indoors and outdoors units are fully explained in the Installation Instructions manual supplied with the equipment. Cooling connections of the GC to the ST Electrical connections of the GC to the ST...
  • Page 26: Refrigeration Connections

    REFRIGERATION CONNECTIONS The indoor units are designed for refrigeration connection to the outdoors units by means of pipes with Flare connectors (completely insulated refrigeration quality copper pipes with ends equipped with Flare nuts). Various lengths of pipes equipped with Flare connectors are available from the factory: •...
  • Page 27: Refrigerant Charge

    REFRIGERANT CHARGE The R-407C charge is only contained in the outdoors unit. The indoors unit contains a small quantity of neutral GAS. For this reason, after having installed the pipe connections, it is imperative to proceed with vacuum draining the con- nections and the indoors unit.
  • Page 28: Electrical Specifications

    ELECTRICAL SPECIFICATIONS FLO inv SX inv K inv Models Power supply~230 V - 50 Hz • • • • • • These characteristics are Current input cooling provided for information purposes Current input heating only and are subject to change Linkings without prior notice.
  • Page 29: Rc4 Infrared Remote Control

    INFRARED REMOTE CONTROL RESET FUNCTION 1. Remove the battery. 2. Simultaneously press these 4 keys until the symbols disappear. 3. Replace the battery. The 4 keys concerned are: Note START / STOP key Flip open the cover/flap to gain access to the controls. Operating mode selection key: COOLING, HEATING, AUTOMATIC COOLING/HEATING REGULATION, VENTILATION, DEHUMIDIFICATION I FEEL key: local temperature sensing...
  • Page 30 1 bis,Avenue du 8 Mai 1945 Saint-Quentin-en-Yvelines 78284 GUYANCOURT Cedex Tél. 33 1 39 44 78 00 Fax 33 1 39 44 11 55 www.airwell.com A A A A A CE Klimatechnik GmbH CE Klimatechnik GmbH CE Klimatechnik GmbH CE Klimatechnik GmbH...

This manual is also suitable for:

Flo 12 invK 9 invSx 12 invK 12 invSx 9 inv