PRESENTATION The range of INVERTER Heatpump splits, compatible with indoor units: These appliance have been optimized to operate with the R-407C coolant which contains no chlorine and has no wall units effect on the ozone layer. Flo inv floor/ceiling units SX inv colorado cassette K inv...
Page 4
The air we breathe is electrically charged, with both positive and negative ions. In closed and urban environments, the concentration of negative ions in the atmosphere is reduced. The ionizer Airwell re-establishes the balance of negative ions in our environment for optimal living comfort.
Page 5
PRESENTATION 2.2 Floor/ceiling unit SX inv Having reduced dimensions (only 190 mm deep), and being aesthetically pleasing, it can be very easily installed in any residential, tertiary or industrial location. Supplied as standard for both wall and ceiling installation, without any on site modifications.
Page 6
Each unit is supplied with general wiring and connection diagrams and specific installation and operation instructions. the recommendations when Each accessory (or kit) is accompanied by technical specifications for fitting and carrying out any work adjustment as required. You can find all these elements on Internet site : http://www.airwell.com...
HEATING CAPACITY wall unit Flo 9 inv Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25° Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25°...
Page 15
HEATING CAPACITY wall unit Flo 12 inv Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25° Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25°...
Page 16
HEATING CAPACITY floor/ceiling SX 9 inv Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25° Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25°...
Page 17
HEATING CAPACITY floor/ceiling Outdoor WB temperature SX 12 inv Indoor DB 15° Indoor DB 20° Indoor DB 25° Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25°...
Page 18
HEATING CAPACITY colorado cassette K 9 inv Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25° Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25°...
Page 19
HEATING CAPACITY colorado cassette K 12 inv Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25° Outdoor WB temperature Indoor DB 15° Indoor DB 20° Indoor DB 25°...
DIMENSIONS Dimensions in mm side view front viex condensing unit GC 9 inv GC 12 inv Clearances 800 mm 150 mm 400 mm 100 mm 500 mm INTAKE top view DISCHARGE...
DIMENSIONS Dimensions in mm side view front view wall units Flo 9 inv Flo 12 inv INTAKE DISCHARGE Clearances Mounting template yo be used for location of indoor 100 mm unit on the wall ceiling 50 mm indoor unit outline...
DIMENSIONS Dimensions in mm colorado cassette K 9 inv K 12 inv DESCRIPTION T bar (suspended ceiling) Suspended ceiling Evaporator Air intake grille Electrical connections Condensates drainage «GAS» valve «LIQUID» valve Fresh air intake Orifice for ducted air distribution into adjacent room...
INSTALLATION indoor unit 1. Choose a location which will provide good air circulation.ensure that no objects or furnishings prevent air circulation. 2. Do not install the unit near a heat source or where it will be exposed to direct sunlight. 3.
CONNECTIONS The pipe and electrical wiring connections to be made between the indoors and outdoors units are fully explained in the Installation Instructions manual supplied with the equipment. Cooling connections of the GC to the ST Electrical connections of the GC to the ST...
REFRIGERATION CONNECTIONS The indoor units are designed for refrigeration connection to the outdoors units by means of pipes with Flare connectors (completely insulated refrigeration quality copper pipes with ends equipped with Flare nuts). Various lengths of pipes equipped with Flare connectors are available from the factory: •...
REFRIGERANT CHARGE The R-407C charge is only contained in the outdoors unit. The indoors unit contains a small quantity of neutral GAS. For this reason, after having installed the pipe connections, it is imperative to proceed with vacuum draining the con- nections and the indoors unit.
ELECTRICAL SPECIFICATIONS FLO inv SX inv K inv Models Power supply~230 V - 50 Hz • • • • • • These characteristics are Current input cooling provided for information purposes Current input heating only and are subject to change Linkings without prior notice.
INFRARED REMOTE CONTROL RESET FUNCTION 1. Remove the battery. 2. Simultaneously press these 4 keys until the symbols disappear. 3. Replace the battery. The 4 keys concerned are: Note START / STOP key Flip open the cover/flap to gain access to the controls. Operating mode selection key: COOLING, HEATING, AUTOMATIC COOLING/HEATING REGULATION, VENTILATION, DEHUMIDIFICATION I FEEL key: local temperature sensing...