7 Troubleshooting Guide
Failure diagnosis of a lens unit
When 3D Recording has abnormalities, please check the following and perform failure diagnosis of a lens unit.
7.1.
Preparation
1. Set up HDC-Z10000 as follows.
• 3D Recording Mode
• 3D display is set to MIX display
• Convergence reset
• Display a guideline.
2. Set up connection as follows.
• Stick 3D inspection chart of attachment in adjustment software on the perpendicular surface of a wall etc.
• Install HDC-Z10000 in the front of 3D inspection chart.
• It fixes so that the horizontal line of 3D inspection chart and guideline may be displayed horizontally on LCD screen.
Figure of connection
* 3D inspection chart is attached to adjustment software.