Panasonic CU-5E36QBU-5 Service Manual

Panasonic CU-5E36QBU-5 Service Manual

Outdoor unit
Hide thumbs Also See for CU-5E36QBU-5:
Table of Contents

Advertisement

Please file and use this manual together with the service manual for Model No. CS-ME5RKUA , CS-ME7RKUA Order No.
PAPAMY1503085AE, CS-ME5SD3UA, CS-ME7SD3UA Order No. PAPAMY1604056CE, CS-E9RKUAW, CS-E12RKUAW,
CS-E18RKUAW, CS-E24RKUAW Order No PAPAMY1501049CE, CS-ME9SB4U Order No PAPAMY1604059CE, CS-E9SD3UAW,
CS-E12SD3UAW,
CS-E18SD3UAW
PAPAMY1503095CE
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or
repair the product or products dealt with in this service information by anyone else could result in serious injury or death.
There are special components used in this equipment which are important for safety. These parts are marked by
Diagrams, Circuit Board Diagrams, Exploded Views and Replacement Parts List. It is essential that these critical parts should be replaced
with manufacturer's specified parts to prevent shock, fire or other hazards. Do not modify the original design without permission of
manufacturer.
In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit.
Order
No.
PAPAMY1604052CE,
WARNING
IMPORTANT SAFETY NOTICE
PRECAUTION OF LOW TEMPERATURE
Order No: PAPAMY1702088CE

Air Conditioner

Outdoor Unit

CU-5E36QBU-5
CS-E12RB4UW,
CS-E18RB4UW
© Panasonic Corporation 2017
Destination
U.S.A.
Canada
Order
No.
in the Schematic
!

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic CU-5E36QBU-5

  • Page 1: Air Conditioner

    Do not modify the original design without permission of manufacturer. PRECAUTION OF LOW TEMPERATURE In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit. © Panasonic Corporation 2017...
  • Page 2: Table Of Contents

    ........46 2. Specifications ............. 5 14. Servicing Mode ..........47 CU-5E36QBU-5 (Wall Mounted & Cassette) ......5 15. Troubleshooting Guide ........49 CU-5E36QBU-5 (Ducted) ......7 15.1 Self Diagnosis Function ......49 3. Dimensions ............26 15.2 Self-diagnosis Method ........52 4. Refrigeration Cycle Diagram ......27 16.
  • Page 3: Safety Precautions

    1. Safety Precautions  Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.  Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model installed. ...
  • Page 4 WARNING 19. During installation, install the refrigerant piping properly before run the compressor. (Operation of compressor without fixing refrigeration piping and valves at opened condition will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.).
  • Page 5: Specifications

    2. Specifications CU-5E36QBU-5 (Wall Mounted & Cassette) Item Unit OUTDOOR UNIT Indoor Unit Combination 2.0kW + 2.0kW + 2.0kW + 2.0kW + 2.5kW Power Source 1 Phase, 208-230V, 60Hz (Power supply from outdoor unit) 10.56 (2.9 ~ 11.5) Capacity BTU/h...
  • Page 6 Item Unit OUTDOOR UNIT Dry Bulb Wet Bulb Maximum °C (°F) 32 (89.6) 23 (73.4) Cooling Minimum °C (°F) 16 (60.8) 11 (51.8) Indoor Operation Range Maximum °C (°F) 30 (86.0) — Heating Minimum °C (°F) 16 (60.8) — Maximum °C (°F) 46 (114.8) 26 (78.8)
  • Page 7: Cu-5E36Qbu-5 (Ducted)

    CU-5E36QBU-5 (Ducted) Item Unit OUTDOOR UNIT Indoor Unit Combination 2.0kW + 2.0kW + 2.0kW + 2.0kW + 2.5kW Power Source 1 Phase, 208-230V, 60Hz (Power supply from outdoor unit) 10.56 (2.9 ~ 11.5) Capacity BTU/h 36000 (9900 ~ 39000) Running Current 21.1 - 19.1...
  • Page 8 Item Unit OUTDOOR UNIT Dry Bulb Wet Bulb Maximum °C (°F) 32 (89.6) 23 (73.4) Cooling Minimum °C (°F) 16 (60.8) 11 (51.8) Indoor Operation Range Maximum °C (°F) 30 (86.0) — Heating Minimum °C (°F) 16 (60.8) — Maximum °C (°F) 46 (114.8) 26 (78.8)
  • Page 9  Multi Split Combination Possibility: A single outdoor unit enables air conditioning of up to five separate rooms. Multi Zone Capacity (kW) CU-5E36QBU-5 CS-ME5RKUA ● CS-ME7RKUA ● CS-E9RKUAW ● Wall CS-E12RKUAW ● CS-E18RKUAW ● CS-E24RKUAW ● CS-ME9SB4U ● 4-Way CS-E12RB4UW ●...
  • Page 10  Indoor Unit : CS-ME5RKUA , CS-ME5SD3UA, CS-ME7RKUA, CS-ME7SD3UA, CS-E9RKUAW, CS-ME9SB4U, CS-E9SD3UAW, CS-E12RKUAW, CS-E12RB4UW, CS-E12SD3UAW, CS-E18RKUAW, CS-E18RB4UW, CS-E18SD3UAW, CS-E24RKUAW  Outdoor Unit : CU-5E36QBU-5 Indoor unit capacity Indoor unit capacity Cooling Capacity(kW) Cooling Capacity(kW) Input Power (W) Input Power (W)
  • Page 11 Indoor unit capacity Cooling Capacity(kW) Input Power (W) MOISTURE REMOVAL VOLUME Total SEER Current, 230V (A) Cooling Room A Room B Room C Room D Room E Total ~ Rating ~ 1.62 1.62 1.62 1.62 1.62 8.10 ~ 11.5 2400 ~...
  • Page 12 Indoor unit capacity Cooling Capacity(BTU/hr) Input Power (W) MOISTURE REMOVAL VOLUME Total SEER Current, 230V (A) Cooling Room A Room B Room C Room D Room E Total Rating Btu/h.W ~ ~ 5500 11000 16500 9900 19800 1430 1790 11.55 ~...
  • Page 13 Indoor unit capacity Cooling Capacity(kW) Input Power (W) MOISTURE REMOVAL VOLUME Total SEER Current, 230V (A) Cooling Room A Room B Room C Room D Room E Total ~ Rating ~ 5520 5520 5520 5520 5520 27600 9900 ~ 39000 2400 ~...
  • Page 14 Indoor unit capacity Heating Capacity(kW) Input Power (W) HSPF MOISTURE REMOVAL VOLUME Total Current, 230V (A) Heating Room A Room B Room C Room D Room E Total ~ Rating ~ Region IV Region V 2.13 4.27 6.40 ~ 1910 ~...
  • Page 15 Indoor unit capacity Heating Capacity(kW) Input Power (W) HSPF MOISTURE REMOVAL VOLUME Total Current, 230V (A) Heating Room A Room B Room C Room D Room E Total ~ Rating ~ Region IV Region V 2.28 2.94 2.94 2.94 11.10 14.2 3000 4260...
  • Page 16 Indoor unit capacity Heating Capacity(BTU/hr) Input Power (W) HSPF MOISTURE REMOVAL VOLUME Total Current, 230V (A) Heating Room A Room B Room C Room D Room E Total ~ Rating ~ Btu/h.W Region IV Region V 7267 14533 21800 8200 28000 1910 2640...
  • Page 17 Indoor unit capacity Heating Capacity(kW) Input Power (W) HSPF MOISTURE REMOVAL VOLUME Total Current, 230V (A) Heating Room A Room B Room C Room D Room E Total ~ Rating ~ Region IV Region V 7809 9997 9997 9997 37800 11600 48500 3000...
  • Page 18 Indoor unit capacity (Ducted Indoor) Cooling Capacity(kW) Inpu t Po wer (W ) MOISTUR E REMOVAL VOL UM E Total SEER Current, 230V (A) Cooling Room A Room B Room C Room D Room E Total Rating W /W ~ ~...
  • Page 19 Indoor unit capacity (Ducted Indoor) Cooling Cap acity(kW) Inpu t Po wer (W) MOISTUR E REMOVAL VOL UM E Total SEER Current, 230V (A) Cooling Room A Room B Room C Room D Room E Total ~ Rating ~ W /W 1.49 1.87 1.87...
  • Page 20 Indoor unit capacity (Ducted Indoor) Cooling Capacity(BTU/hr) Inpu t Po wer (W ) MOISTUR E REMOVAL VOL UM E Total SEER Current, 230V (A) Cooling Room A Room B Room C Room D Room E Total ~ Rating ~ Btu/h.W 5500 11000 16500...
  • Page 21 Indoor unit capacity (Ducted Indoor) Cooling Capacity(BTU/hr) Inpu t Po wer (W ) MOISTUR E REMOVAL VOL UM E Total SEER Current, 230V (A) Cooling Room A Room B Room C Room D Room E Total ~ Rating ~ Btu/h.W 5096 6372 6372...
  • Page 22 Indoor unit capacity (Ducted Indoo r) Heating Capacity(kW) Input Power (W) HSPF MOISTURE REMOVAL VOLUME Total Current, 230V (A) Heating Room A Room B Room C Room D Room E Total ~ Rating ~ Region IV Region V 2.13 4.27 6.40 ~...
  • Page 23 Indoor unit capacity (Ducted Indoo r) Heating Capacity(kW) Input Power (W) HSPF MOISTURE REMOVAL VOLUME Total Current, 230V (A) Heating Room A Room B Room C Room D Room E Total ~ Rating ~ Region IV Region V 1.10 2.19 2.19 2.19 3.43...
  • Page 24 Indoor unit capacity (Ducted Indoo r) Heating Capacity(BTU/hr) Input Power (W) HSPF MOISTURE REMOVAL VOLUME Total Current, 230V (A) Heating Room A Room B Room C Room D Room E Total ~ Rating ~ Btu/h.W Region IV Region V 7267 14533 21800 8200...
  • Page 25 Indoor unit capacity (Ducted Indoo r) Heating Capacity(BTU/hr) Input Power (W) HSPF MOISTURE REMOVAL VOLUME Total Current, 230V (A) Heating Room A Room B Room C Room D Room E Total ~ Rating ~ Btu/h.W Region IV Region V 6019 7705 12038 12038...
  • Page 26: Dimensions

    3. Dimensions...
  • Page 27: Refrigeration Cycle Diagram

    4. Refrigeration Cycle Diagram...
  • Page 28: Block Diagram

    5. Block Diagram...
  • Page 29: Wiring Connection Diagram

    6. Wiring Connection Diagram...
  • Page 30: Electronic Circuit Diagram

    7. Electronic Circuit Diagram...
  • Page 31: Printed Circuit Board

    8. Printed Circuit Board Main Printed Circuit Board...
  • Page 32: Noise Filter Printed Circuit Board

    Noise Filter Printed Circuit Board Display Printed Circuit Board...
  • Page 33: Installation Information

    9. Installation Information Check Points...
  • Page 34: Installation Instruction

    10. Installation Instruction 10.1 Select The Best Location  If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the condenser is not obstructed.  There should not be any animal or plant which could be affected by hot air discharged.
  • Page 35: Install The Outdoor Unit

    Outdoor Unit Installation Guidelines  Where a wall or other obstacle is in the path of outdoor unit’s intake or exhaust airflow, follow the installation guidelines below.  For any of the below installation patterns, the wall height on the exhaust side should be 47-1/4" (1200 mm) or less.
  • Page 36: Evacuation Of The Equipment

    CUTTING AND FLARING THE PIPING 1. Please cut using pipe cutter and then remove the burrs. 2. Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused. Turn the piping end down to avoid the metal powder entering the pipe. 3.
  • Page 37: Connect The Cable To The Outdoor Unit

    10.5 Connect The Cable To The Outdoor Unit 1. Remove Plugs. 2. Fix the conduit connectors to the knock out holes with lock-nuts, then secure them. 3. Connecting wire between indoor unit and outdoor unit should be UL listed or CSA approved 4 conductor wires minimum AWG16 in accordance with local electric codes.
  • Page 38: Disposal Of Outdoor Unit Drain Water

    10.7 Disposal Of Outdoor Unit Drain Water  If a drain elbow is used, the unit should be placed on a stand which is taller than 1-31/32" (50 mm).  If the unit is used in an area where temperature falls below 32°F (0°C) for 2 or 3 days in succession, it is recommended not to use a drain elbow, for the drain water freezes and the fan will not rotate.
  • Page 39: Operation Control

    11. Operation Control 11.1 Cooling Operation 11.1.1 Outdoor fan control  When cooling operation is enabled, based on outdoor ambient temperature, fan motor control will be adjusted according to figure below: 11.1.2 Annual Cooling control  This control is to enable cooling operation when outdoor ambient temperature is low. ...
  • Page 40: Heating Operation

    11.2 Heating Operation 11.2.1 Outdoor fan control  When heating operation is enabled, based on outdoor ambient temperature, fan motor control will be adjusted according to figure below for Heating overload control: 11.2.2 Heating Room Temp Sampling Control  To improve the judgment accuracy, indoor room temperature sampling starts when any indoor unit has stopped capability supplied (heating thermo-off) during heating operation with compressor ON, outdoor unit will send signal to all thermo-off indoor units to ON fan motor and get room temperature sample.
  • Page 41: Simultaneous Operation Control

    12. Simultaneous Operation Control  Operation modes which can be selected using the remote control unit: Automatic, Cooling, Dry, Heating and e-ion operation mode.  Types of operation modes which can be performed simultaneously Cooling operation and Cooling, Dry or e-ion operation. Heating operation and Heating operation.
  • Page 42: Protection Control

    13. Protection Control 13.1 Freeze Prevention control (Cool)  When received freeze prevention signal from indoor unit, the compressor frequency changes according to indoor heat exchanger temperature.  When indoor unit request capability OFF due to freeze condition, immediately the capability supply to targeted indoor unit stops.
  • Page 43: Cooling Overload Control (Cool)

    13.5 Cooling overload control (Cool)  This control detect outdoor pipe temperature and perform the compressor frequency restriction during cooling operation.  The compressor will be stopped to avoid compressor overloading. COMP. ON 14.0°F (-10.0°C) 10.4°F (-12.0°C) COMP. OFF Outdoor Air Temperature 13.6 Heating overload control (Heat) ...
  • Page 44: Extreme Low Temperature Compressor Low Pressure Protection Control (Heat)

    If the running current does not exceed X value for 5 seconds, compressor frequency will increase.  However, if total outdoor unit running current exceeds Y value, compressor will be stopped immediately for 3 minutes. CU-5E36QBU-5 Operation Mode X (A) Y (A) 19.43...
  • Page 45: Ipm (Power Transistor) Protection Control

     The first 30 minutes of cooling operation, (A) will be applied. 13.12 IPM (power transistor) Protection Control  Overheating Prevention Control If IPM temperature rises to 176°F (80°C), outdoor fan speed will be increased. When the IPM temperature rises to 203°F (95°C), compressor operation will stop immediately. Compressor operation restarts when temperature decreases to 194°F (90°C).
  • Page 46: Protection Control

    13.15 Valve close detection control  This control detects 3-way valve close condition to prevent damage to refrigerant cycle.  Start conditions: For all connected indoor units, if Indoor intake temperature — indoor piping temperature are between 28.4°F (-2°C) and 35.6°F (2°C) continuously for 5 minutes after compressor ON at first cooling operation. The first cooling operation is defined as cooling operation is ON for less than 8 minutes after new installation or after pump down.
  • Page 47: Servicing Mode

    14. Servicing Mode 14.1.1 Pump down operation (SW1)  Operate the pump down process according to the following procedure. Confirm the valve on the liquid side and gas side are open. Press PUMP DOWN button (SW1) on the Service PCB inside the outdoor unit for more than 5 seconds. Pump down (cooling) operation is performed for 15 minutes.
  • Page 48: Wiring Error Check

    14.1.3 Wiring Error Check  The unit capable to correct the wiring error automatically by following procedures. Confirm the valve on the liquid side and gas side is open. Press WIRING CHECK button (SW3) on the Service PCB inside the outdoor unit for more than 10 seconds to start wiring check operation.
  • Page 49: Troubleshooting Guide

    15. Troubleshooting Guide 15.1 Self Diagnosis Function  The display screen of wireless remote control unit and the self-diagnosis LEDs (green) on the outdoor printed circuit board in the outdoor unit can be used to identify the location of the problem. Refer to the table below to identify and solve the cause of the problem, and then re-start the air conditioner system.
  • Page 52: Self-Diagnosis Method

    15.2 Self-diagnosis Method 15.2.1 H11 (Indoor/Outdoor Abnormal Communication) Malfunction Decision Conditions  During standby and operation of cooling and heating, the data received from outdoor unit in indoor unit signal transmission is checked whether it is normal. Malfunction Caused  Faulty outdoor unit PCB.
  • Page 53 Communication voltage measurement: To determine if outdoor PCB or indoor PCB is faulty:  Start with outdoor terminal first.  Remove terminal 3 wire.  Measure with a multimeter (voltage in DC range).  If it is never constant, outdoor PCB is good fluctuating in between 10-70Vdc, outdoor PCB is in good condition.
  • Page 54 15.2.2 H12 (Indoor Unit Capacity Unmatched) Malfunction Decision Conditions  Occur when connect in a multi free inverter system.  However, for single split system (ONLY: CS-E21~24DKE; I/D capacity more than 5.0kW), when indoor and outdoor are disconnected from one another, H12 will appear but with conditions. Malfunction Caused ...
  • Page 55 15.2.3 H15 (Compressor Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heating, the temperatures detected by the compressor discharge temperature sensor are used to determine sensor errors. Malfunction Caused  Faulty connector connection.  Faulty sensor.
  • Page 56 15.2.4 H16 (Outdoor Current Transformer (CT) Abnormality) Malfunction Decision Conditions  A current transformer (CT) is detected by checking the compressor running frequency (≥ rated frequency) and CT detected input current (less than 1.25A) for continuously 20 seconds. Malfunction Caused ...
  • Page 57 15.2.5 H27 (Outdoor Air Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heating, the temperatures detected by the outdoor intake air temperature sensor are used to determine sensor errors. Malfunction Caused  Faulty connector connection. ...
  • Page 58 15.2.6 H28 (Outdoor Heat Exchanger Temperature Sensor 1 Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heating, the temperatures detected by the outdoor pipe temperature sensor are used to determine sensor errors. Malfunction Caused  Faulty connector connection. ...
  • Page 59 15.2.7 H32 (Outdoor Heat Exchanger Temperature Sensor 2 Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heating, the temperatures detected by the outdoor pipe temperature sensor 2 are used to determine sensor errors. Malfunction Caused  Faulty connector connection.
  • Page 60 15.2.8 H33 (Indoor / Outdoor Misconnection Abnormality) Malfunction Decision Conditions  The supply power is detected for its requirement by the indoor/outdoor transmission. Malfunction Caused  Wrong models interconnected.  Wrong indoor unit and outdoor unit PCBs used. Troubleshooting For safety reason and to prevent component breakdown, always switch off the power before Caution remove and connect the component.
  • Page 61 15.2.9 H36 (Outdoor Gas Pipe Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heating, the temperatures detected by the outdoor gas pipe temperature sensor are used to determine sensor errors. Malfunction Caused  Faulty connector connection. ...
  • Page 62 15.2.10 H37 (Outdoor Liquid Pipe Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heating, the temperatures detected by the outdoor liquid pipe temperature sensor are used to determine sensor errors. Malfunction Caused  Faulty connector connection. ...
  • Page 63 15.2.11 H97 (Outdoor Fan Motor Mechanism Locked) Malfunction Decision Conditions  The rotation speed detected by the Hall IC during fan motor operation is used to determine abnormal fan motor. Malfunction Caused  Operation stop due to short circuit inside the fan motor winding. ...
  • Page 64 15.2.12 H98 (Indoor High Pressure Protection) Malfunction Decision Conditions  During heating operation, the temperature detected by the indoor pipe temperature sensor is above 60°C. Malfunction Caused  Clogged air filter of the indoor unit.  Dust accumulation on the indoor unit heat exchanger. ...
  • Page 65 15.2.13 H99 (Indoor Operating Unit Freeze Protection) Malfunction Decision Conditions  During cooling operation, anti-freezing control take place when indoor pipe temperature is lower than 0°C. Malfunction Caused  Clogged air filter of the indoor unit.  Dust accumulation on the indoor unit heat exchanger. ...
  • Page 66 15.2.14 F11 (4-Way Valve Switching Abnormality) Malfunction Decision Conditions  During heating operation, when (liquid pipe temperature – outdoor pipe temperature) is below -5°C.  During cooling operation, when (outdoor pipe temperature – liquid pipe temperature) is below -5°C. Malfunction Caused ...
  • Page 67 15.2.15 F17 (Indoor Standby Units Freezing Abnormality) Malfunction Decision Conditions  When the difference between indoor intake air temperature and indoor pipe temperature is above 10°C or indoor pipe temperature is below -1.0°C. Malfunction Caused  Wrong wiring connection.  Faulty sensor.
  • Page 68 15.2.16 F90 (Power Factor Correction (PFC) Circuit Protection) Malfunction Decision Conditions  During startup and operation of cooling and heating, when PFC protection circuitry at the outdoor unit main PCB senses low DC voltage level (below 280Vdc). Malfunction Caused  Low DC voltage due to power supply drop.
  • Page 69 15.2.17 F91 (Refrigeration Cycle Abnormality) Malfunction Decision Conditions  Gas shortage detection I: A gas shortage is detected by checking the CT-detected input current value and the compressor running frequency. During startup and operating of cooling and heating, input current < 8.78/256 (A/Hz) x compressor running frequency + 0.25.
  • Page 70 15.2.18 F93 (Compressor Abnormal Revolution) Malfunction Decision Conditions  A compressor rotation failure is detected by checking the compressor running condition through the position detection circuit. Malfunction Caused  Compressor terminal disconnect.  Outdoor PCB malfunction. Abnormality Judgment:  4 times happen within 20 minutes. Troubleshooting For safety reason and to prevent component breakdown, always switch off the power before...
  • Page 71 15.2.19 F94 (Compressor Discharge Pressure Overshoot Protection) Malfunction Decision Conditions  During operation of cooling and heating, when the outdoor unit high pressure switch is open (4.15MPa and above). Malfunction Caused  Clogged air filter of indoor unit.  Dust accumulation on the indoor/outdoor unit heat exchanger. ...
  • Page 72 15.2.20 F96 (Power Transistor Module Overheating Protection) Malfunction Decision Conditions  Compressor Overheating: During operation of cooling and heating, when the compressor OL is activated.  Heat Sink Overheating: During operation of cooling and heating, when heat sink temperature data (90°C) is detected by the heat sink temperature sensor.
  • Page 73 15.2.21 F97 (Compressor Overheating Protection) Malfunction Decision Conditions  During operation of cooling and heating, when compressor discharge pipe temperature data (120°C) is detected by the compressor discharge pipe temperature sensor. Malfunction Caused  Refrigerant shortage (refrigerant leakage).  2/3 way valve closed. ...
  • Page 74 15.2.22 F98 (Total Running Current Protection) Malfunction Decision Conditions  During operation of cooling and heating, when an input over-current (20.0A) is detected by checking the input current value being detected by current transformer (CT) with the compressor running. Malfunction Caused ...
  • Page 75 15.2.23 F99 (Outdoor Direct Current (DC) Peak Protection) Malfunction Decision Conditions  During operation of cooling and heating, when an output over-current is detected by checking the current that flows in the inverter DC Peak sensing circuitry. Malfunction Caused  DC peak due to compressor failure.
  • Page 76: Disassembly And Assembly Instructions

    16. Disassembly and Assembly Instructions WARNING High Voltage is generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding with repair work. Failure to heed this caution may result in electric shocks. 16.1 Outdoor Unit Removal Procedure Caution! When handling electronic controller, be careful of electrostatic discharge.
  • Page 77 3. Remove the particular plate (remove the 3 screws). Fig. 3 4. Remove the particular plate (remove the 8 screws). Fig. 4 16.1.3 Removing the Cabinet Front Plate 5. Remove the cabinet front plate (remove the 7 screws). Fig. 5...
  • Page 78: Fan Motor

    16.1.4 Removing the Control P.C. Board 6. Remove the cover by release the screw. Fig. 6 7. Disconnect the connectors (lead wires of the compressor, sensors, and others). 8. Release the Control P.C. Board tab to remove the Control P.C. Board. Fig.
  • Page 79: Technical Data

    17. Technical Data 17.1 Operation Characteristics 17.1.1 One Indoor Unit Operation  Cooling Characteristic [Condition] Room temperature: 80.0°F (26.7°C) (DBT), 67.0°F (19.4°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz A) Indoor unit capacity: Cooling (2.0: CS-ME7QKUA), service mode frequency = 20 Hz ME7QKUA 64.000 63.000...
  • Page 80  Cooling Characteristic [Condition] Room temperature: 80.0°F (26.7°C) (DBT), 67.0°F (19.4°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz B) Indoor unit capacity: Cooling (2.5: CS-E9RKUAW), service mode frequency = 20 Hz E9RKUAW 64.000 63.000 62.000 61.000 60.000...
  • Page 81  Cooling Characteristic [Condition] Room temperature: 80.0°F (26.7°C) (DBT), 67.0°F (19.4°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz C) Indoor unit capacity: Cooling (3.2: CS-E12RKUAW), service mode frequency = 34 Hz E12RKUAW 60.000 59.000 58.000 57.000 56.000...
  • Page 82  Cooling Characteristic [Condition] Room temperature: 80.0°F (26.7°C) (DBT), 67.0°F (19.4°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz D) Indoor unit capacity: Cooling (5.0: CS-E18RKUAW), service mode frequency = 49 Hz E18RKUAW 61.000 60.000 59.000 58.000 57.000...
  • Page 83  Heating Characteristic [Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz A) Indoor unit capacity: Heating (2.0: CS-ME7QKUA), service mode frequency = 39 Hz ME7QKUA 115.000 110.000 105.000 100.000 95.000...
  • Page 84  Heating Characteristic [Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz B) Indoor unit capacity: Heating (2.5: CS-E9RKUAW), service mode frequency = 39 Hz E9RKUAW 115.000 110.000 105.000 100.000 95.000...
  • Page 85  Heating Characteristic [Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz C) Indoor unit capacity: Heating (3.2: CS-E12RKUAW), service mode frequency = 47 Hz E12RKUAW 115.000 110.000 105.000 100.000 95.000...
  • Page 86  Heating Characteristic [Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz D) Indoor unit capacity: Heating (5.0: CS-E18RKUAW), service mode frequency = 55 Hz E18RKUAW 115.000 110.000 105.000 100.000 95.000...
  • Page 87 17.1.2 Two Indoor Unit Operation  Cooling Characteristic [Condition] Room temperature: 80.0°F (26.7°C) (DBT), 67.0°F (19.4°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz A) Indoor unit capacity: Cooling (2.0 + 2.5: CS-ME7QKUA + CS-E9RKUAW), service mode frequency = 49 Hz ME7QKUA E9RKUAW 61.000...
  • Page 88  Cooling Characteristic [Condition] Room temperature: 80.0°F (26.7°C) (DBT), 67.0°F (19.4°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz B) Indoor unit capacity: Cooling (2.0 + 3.2: CS-ME7QKUA + CS-E12RKUAW), service mode frequency = 49 Hz ME7QKUA E12RKUAW 61.000...
  • Page 89  Cooling Characteristic [Condition] Room temperature: 80.0°F (26.7°C) (DBT), 67.0°F (19.4°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz C) Indoor unit capacity: Cooling (2.0 + 5.0: CS-ME7QKUA + CS-E18RKUAW), service mode frequency = 51 Hz ME7QKUA E18RKUAW 64.000...
  • Page 90  Cooling Characteristic [Condition] Room temperature: 80.0°F (26.7°C) (DBT), 67.0°F (19.4°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz D) Indoor unit capacity: Cooling (2.5 + 3.2: CS-E9RKUAW + CS-E12RKUAW), service mode frequency = 49 Hz E9RKUAW E12RKUAW 62.000...
  • Page 91  Cooling Characteristic [Condition] Room temperature: 80.0°F (26.7°C) (DBT), 67.0°F (19.4°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz E) Indoor unit capacity: Cooling (2.5 + 5.0: CS-E9RKUAW + CS-E18RKUAW), service mode frequency = 51 Hz E9RKUAW E18RKUAW 64.000...
  • Page 92  Cooling Characteristic [Condition] Room temperature: 80.0°F (26.7°C) (DBT), 67.0°F (19.4°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz F) Indoor unit capacity: Cooling (3.2 + 5.0: CS-E12RKUAW + CS-E18RKUAW), service mode frequency = 53 Hz E12RKUAW E18RKUAW 64.000...
  • Page 93  Heating Characteristic [Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz A) Indoor unit capacity: Heating (2.0 + 2.5: CS-ME7QKUA + CS-E9RKUAW), service mode frequency = 58 Hz ME7RKUA E9RKUAW 110.000...
  • Page 94  Heating Characteristic [Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz B) Indoor unit capacity: Heating (2.0 + 3.2: CS-ME7QKUA + CS-E12RKUAW), service mode frequency = 64 Hz ME7QKUA E12RKUAW 110.000...
  • Page 95  Heating Characteristic [Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz C) Indoor unit capacity: Heating (2.0 + 5.0: CS-ME7QKUA + CS-E18RKUAW), service mode frequency = 68 Hz ME7QKUA E18RKUAW 110.000...
  • Page 96  Heating Characteristic [Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz D) Indoor unit capacity: Heating (2.5 + 3.2: CS-E9RKUAW + CS-E12RKUAW), service mode frequency = 64 Hz E9RKUAW E12RKUAW 110.000...
  • Page 97  Heating Characteristic [Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz E) Indoor unit capacity: Heating (2.5 + 5.0: CS-E9RKUAW + CS-E18RKUAW), service mode frequency = 68 Hz E9RKUAW E18RKUAW 110.000...
  • Page 98  Heating Characteristic [Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz F) Indoor unit capacity: Heating (3.2 + 5.0: CS-E12RKUAW + CS-E18RKUAW), service mode frequency = 73 Hz E12RKUAW E18RKUAW 110.000...
  • Page 99 17.1.3 Three Indoor Unit Operation  Cooling Characteristic [Condition] Room temperature: 80.0°F (26.7°C) (DBT), 67.0°F (19.4°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz A) Indoor unit capacity: Cooling (2.0 + 2.5 + 3.2: CS-ME7QKUA + CS-E9RKUAW + CS-E12RKUAW), service mode frequency = 55 Hz ME7QKUA E9RKUAW...
  • Page 100  Cooling Characteristic [Condition] Room temperature: 80.0°F (26.7°C) (DBT), 70.0°F (19.4°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz B) Indoor unit capacity: Cooling (2.0 + 2.5 + 5.0: CS-ME7QKUA + CS-E9RKUAW + CS-E18RKUAW), service mode frequency = 57 Hz ME7QKUA E9RKUAW E18RKUAW...
  • Page 101  Cooling Characteristic [Condition] Room temperature: 80.0°F (26.7°C) (DBT), 70.0°F (19.4°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz C) Indoor unit capacity: Cooling (2.0 + 3.2 + 5.0: CS-ME7QKUA + CS-E12RKUAW + CS-E18RKUAW), service mode frequency = 59 Hz ME7QKUA E12RKUAW E18RKUAW...
  • Page 102  Cooling Characteristic [Condition] Room temperature: 80.0°F (26.7°C) (DBT), 70.0°F (19.4°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz D) Indoor unit capacity: Cooling (2.5 + 3.2 + 5.0: CS-E9RKUAW + CS-E12RKUAW + CS-E18RKUAW), service mode frequency = 59 Hz E9RKUAW E12RKUAW E18RKUAW...
  • Page 103  Heating Characteristic [Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz A) Indoor unit capacity: Heating (2.0 + 2.5 + 3.2: CS-ME7QKUA + CS-E9RKUAW + CS-E12RKUAW), service mode frequency = 77 Hz ME7QKUA E9RKUAW E12RKUAW...
  • Page 104  Heating Characteristic [Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz B) Indoor unit capacity: Heating (2.0 + 2.5 + 5.0: CS-ME7QKUA + CS-E9RKUAW + CS-E18RKUAW), service mode frequency = 77 Hz ME7QKUA E9RKUAW E18RKUAW...
  • Page 105  Heating Characteristic [Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz C) Indoor unit capacity: Heating (2.0 + 3.2 + 5.0: CS-ME7QKUA + CS-E12RKUAW + CS-E18RKUAW), service mode frequency = 82 Hz ME7QKUA E12RKUAW E18RKUAW...
  • Page 106  Heating Characteristic [Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz D) Indoor unit capacity: Heating (2.5 + 3.2 + 5.0: CS-E9RKUAW + CS-E12RKUAW + CS-E18RKUAW), service mode frequency = 82 Hz E9RKUAW E12RKUAW E18RKUAW...
  • Page 107 17.1.4 Four Indoor Unit Operation  Cooling Characteristic [Condition] Room temperature: 80.0°F (26.7°C) (DBT), 70.0°F (19.4°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz A) Indoor unit capacity: Cooling (2.0 + 2.5 + 3.2 + 5.0: CS-ME7QKUA + CS-E9RKUAW + CS-E12RKUAW + CS-E18RKUAW), service mode frequency = 65 Hz ME7QKUA E9RKUAW...
  • Page 108  Heating Characteristic [Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz A) Indoor unit capacity: Heating (2.0 + 2.5 + 3.2 + 5.0: CS-ME7QKUA + CS-E9RKUAW + CS-E12RKUAW + CS-E18RKUAW), service mode frequency = 86 Hz ME7QKUA E9RKUAW...
  • Page 109 17.1.5 Five Indoor Unit Operation  Cooling Characteristic [Condition] Room temperature: 80.0°F (26.7°C) (DBT), 70.0°F (19.4°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz A) Indoor unit capacity: Cooling (2.0 + 2.5 + 3.2 + 3.2 + 5.0: CS-ME7QKUA + CS-E9RKUAW + CS-E12RKUAW + CS-E12RKUAW + CS-E18RKUAW), service mode frequency = 75 Hz ME7QKUA E9RKUAW...
  • Page 110  Heating Characteristic [Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT) Operation condition: High fan speed Piping Length: 7.5m (24.6 ft) 230V 60Hz A) Indoor unit capacity: Heating (2.0 + 2.5 + 3.2 + 3.2 + 5.0: CS-ME7QKUA + CS-E9RKUAW + CS-E12RKUAW + CS-E12RKUAW + CS-E18RKUAW), service mode frequency = 95 Hz ME7QKUA E9RKUAW...
  • Page 111: Capacity Table

    17.1.6 Capacity Table 17.1.6.1 Cooling Cooling: 60Hz, 230V Maximum capacity and Input power Outdoor Indoor Air Temp. DB/WB °C (°F) Combination Temp. 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) (Capacity) °C (°F) Input Input Input Input Input Input...
  • Page 112 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 113 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 114 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 115 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 116 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 117 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 118 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 119 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 120 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 121 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 122 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 123 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 124 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 125 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 126 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 127 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 128 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 129 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 130 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 131 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 132 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 133 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 134 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 135 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 136 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 137 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 138 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 139 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 140 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 141 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 142 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 143 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 144 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 145 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 146 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 147 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 148 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 149 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 150 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 151 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 152 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 153 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 154 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 155 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 156 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 157 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 158 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 159 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 160 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 161 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 162 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 163 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 164 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 165 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 166 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 167 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 168 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 169 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 170 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 171 Indoor Air Temp. DB/WB °C (°F) Outdoor Combination 27/16 (80.6/60.8) 27/17.5 (80.6/63.5) 27/18 (80.6/64.4) 27/19 (80.6/66.2) 27/22 (80.6/71.6) 27/24 (80.6/75.2) Temp. (Capacity) °C (°F) Input Input Input Input Input Input Total Q Total Q Total Q Total Q Total Q Total Q Power Power...
  • Page 172 17.1.6.2 Heating Heating: 60Hz, 230V Maximum capacity and Input power Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2)
  • Page 173 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 174 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 175 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 176 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 177 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 178 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 179 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 180 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 181 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 182 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 183 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 184 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 185 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 186 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 187 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 188 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 189 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 190 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 191 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 192 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 193 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 194 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 195 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 196 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 197 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 198 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 199 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 200 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 201 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 202 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 203 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 204 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 205 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 206 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 207 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 208 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 209 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 210 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 211 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 212 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 213 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 214 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 215 Outdoor Air Temp. DB/WB °C (°F) Indoor Combination 16/15 15/14 -10/-11 Temp. 10/9 (50.0/48.2) 7/6 (44.6/42.8) 6/5 (42.8/41.0) 2/1 (35.6/33.8) 0/-1 (32.0/30.2) -5/-6 (23.0/21.2) -7/-8 (19.4/17.6) -15/- (5.0/-) -21/- (-5.0/-) (Capacity) (60.8/59.0) (59.0/57.2) (14.0/12.2) °C (°F) Input Input Input Input Input Input Input...
  • Page 216: List

    18. Exploded View and Replacement Parts List Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
  • Page 217 SAFETY REF.NO. DESCRIPTION & NAME QTY. CU-5E36QBU-5 REMARK BASE PAN ASS'Y CWD52K1364A FAN MOTOR BRACKET CWD54K1081 SCREW-BRACKET FAN MOTOR CWH551217 CONDENSER COMPLETE ACXB32C02140 FAN MOTOR L6CBYYYL0116 SCREW-FAN MOTOR MOUNT CWH551323 PROPELLER FAN ASSY CWH03K1075 CWH561092 COMPRESSOR 5KD240XAL21 BUSHING - COMPRESSOR MOUNT...
  • Page 218 SAFETY REF.NO. DESCRIPTION & NAME QTY. CU-5E36QBU-5 REMARK TERMINAL BOARD ASS'Y (L, N) CWA28K1195 TERMINAL BOARD ASS'Y (1, 2, 3) CWA28K1196 CONTROL BOARD COVER (TOP PCB) CWH131613 CABINET TOP PLATE CWE03C1159 CABINET FRONT PLATE-COMPLETE CWE06C1510 CABINET SIDE PLATE CWE041792A CABINET REAR PLATE-COMPLETE...

Table of Contents