Futek IHH500 Quick Start Manual

Intelligent handheld display
Hide thumbs Also See for IHH500:

Advertisement

IHH500
Intelligent Handheld Display
Sensor Solutions Source
Load · Torque · Pressure · Multi Component · Calibration · Instruments · Software
www.futek.com
Quick Start Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IHH500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Futek IHH500

  • Page 1 Quick Start Guide IHH500 Intelligent Handheld Display Sensor Solutions Source Load · Torque · Pressure · Multi Component · Calibration · Instruments · Software www.futek.com...
  • Page 2 Getting Help TECHNICAL SUPPORT For more IHH500 support, please visit: http://www.futek.com/ihh500/support.aspx Drawing Number: SP1189 FUTEK reserves the right to modify its design and specifications without notice. Please visit http://www.futek.com/salesterms for complete terms and conditions. 10 Thomas, Irvine, CA 92618 USA...
  • Page 3: Table Of Contents

    Table of Contents Display Features ..... 4 Alarm and Relay Quick Setup ....15 Buttons .
  • Page 4: Display Features

    Display Features Power Connector Valley Value IHH500 USB Connector Sampling Rate (Compatible with USB 2.0 Only) Battery Indicator +2.00001 Peak Output Connector +2.00000 mV/V Larger Font +1.99999 Valley 01 Gross 5 SPS Sensor Connector Display Options Battery Display 16×4 Character LCD...
  • Page 5: Buttons

    Buttons Toggles between engineering units (force, Battery Battery Battery Battery Battery Displays Battery Life torque, pressure and displacement) and the Enter Battery Enter Enter Battery Enter Enter Battery Unit Unit Enter Unit Battery Unit Unit Enter Enter Enter Unit standard mV/V. Enter IN MENU MODE: Unit...
  • Page 6: Connector Pin Configuration

    Connector Pin Configuration Power Output Sensor page 7 page 7 page 7 page 8...
  • Page 7: Wiring Layout

    2 (positive) analog current output return USB PORT CONNECTIONS –R1 solid state relay 1 (negative) (COMPATIBLE WITH USB 2.0 ONLY) –R2 solid state relay 2 (negative) SYMBOL VBUS –D http://www. IHH500 Wiring Connection Examples: futek.com/files/Pdf/Manuals_and_Technical_ Documents/IHH500Wiring.pdf...
  • Page 8 Leading pulse from sensor PLAG Lagging pulse from sensor Note: Cable should be connected to pin G, ground, and 12-PIN SENSOR TO IHH500 BINDER ASSEMBLY should be grounded on one end, either the sensor side or the IHH500 connection side.
  • Page 9 CONNECTION TIPS The +/- Excitation and +/- Signal The IHH500 Elite is callable of If the Leading Pulse Pin L leads Pin M the connections are used with mV/V output interacting with encoders, such as those Encoder count will increase and if the...
  • Page 10: Profile Quick Setup (Calibration)

    Profile Quick Setup (Calibration) The IHH500 can store up to 15 profiles with channel 2 through 15 being user selectable. Menu Sensor Capacity Sensor Profile Sensitivity (+) New Channel 10. Sensitivity (–) if applicable Set channel using left and right 11.
  • Page 11 Enter can be used for Yes, and Back for No. digit to change it into a decimal point. IHH500 Elite supports Encoders through Pulse profiles. Sensitivity (+) must be entered. If only one direction is selected, then sensitivity (+) will be applied to both directions Current profiles cannot be set up manually and must be set up of output or negative direction output.
  • Page 12: Teds And Channel Select

    Auto Detection — Sets the IHH500 to automatically load The TEDS chip should be placed within TEDS information upon power 5ft. of the IHH500 sensor connection to maintain proper power. Typically the TEDS chip is placed in the sensor binder connector.
  • Page 13: Profile Lockout And Lcd Settings

    Contrast The default lockout password will be the serial number on b. Unlock Profile b. Brightness the back of the IHH500. The password can be changed to a c. Change Password c. Auto LCD Off new numerical combination. The LCD contrast and brightness can be set to maximum and the levels can be saved as default for all future usage of the IHH500.
  • Page 14: Analog Output Quick Setup

    Back to main menu Current Output for both directions from the sensor. 10. Back again to exit 10. Select Enable A Tare function will affect the reading 11. Back to exit to main menu on the IHH500 as well as the Analog Output.
  • Page 15: Alarm And Relay Quick Setup

    Alarm and Relay Quick Setup ALARM SETUP Alarm Configuration and Alarm Activity: Alarm Limit set points: 11. Menu Menu 12. System Settings Sensor Profile 13. Alarm Config (Latched or Non-Latched) Edit Channel (Choose appropriate channel) 14. Alarm Activity (Enable or Disable) Limit &...
  • Page 16 TIPS FOR ALARMS AND RELAYS Alarm Relay 1 is mapped to Alarm High Threshold limits are set as a percentage Peak will flash on the IHH500 for an and Alarm Relay 2 is mapped to Alarm of the capacity of the sensor.
  • Page 17: Data Logging

    Data logging is the ability to capture readings over a specified time period for later evaluation. The Data logging information can be uploaded into the FUTEK SENSIT software and further exported into other programs, such as Microsoft Excel. DATA LOGGING QUICK SETUP...
  • Page 18 TIPS FOR USING DATA LOGGING The IHH500 can store up to 21,000 data The data logging information is lost When the data logging session is logging points. Each point is a captured when power is turned off on the IHH500.
  • Page 19: Sensit Test And Measurement Software

    SENSIT Test and Measurement Software ™ The IHH500 can be used with the FUTEK SENSIT software, which can be purchased separately or evaluated through a free trial version available on the FUTEK website. FUNCTIONS AVAILABLE IN SENSIT WITH THE TO SETUP DATA LOGGING IN SENSIT FOR IHH500:...
  • Page 20: Performance Review

    Performance Review INPUT POWER ADAPTER PARAMETER UNIT PARAMETER Input Range 1 –500 mV/V nom. Input 90–264 VAC 0.5 A 50/60 Hz Input Range 2 –12 Output 12 VDC Input Range 3 OUTPUT PARAMETER UNIT Analog Voltage –5 Analog Current...
  • Page 21: Specifications

    SPS/5 for sampling rates more than 1200 SPS if: Note: Internally limited and protected to 110V/100 mA 1. ASCII stream output is deactivated 2. IHH500 is not connected to computer PASSWORDS 3. All relays are disabled • Default Password: 0000000 4.
  • Page 22: Setting Sampling Rate And Number Of Digits

    4800 sps at preset intervals. Sampling Rate Digits Select Increasing the sampling rate may increase the noise as the IHH500 becomes more sensitive to input changes. The decimal point is floating on the IHH500 which means with 4 decimal points the format will automatically adjust from 0000 to 0.000.
  • Page 23: Troubleshooting

    IHH500 from the troubleshooting any questions in a profile setup.