Parameter
Serial Timer:
Serial Value:
*) The serial port of the unit can operate in either "PC-Mode" or in
"Printer Mode".
With "PC-Mode", the unit receives a request string and responds with a
corresponding data string. For details of the protocol see separate description
"SERPRO".
With "Printer Mode" the unit sends data without any request and under Timer
control as described subsequently.
As soon as the unit receives a character, it automatically switches over to PC
Mode and operates according to protocol. When for a period of 20 s no
character has been received, the unit switches automatically back to
"Printer Mode" and starts cyclic data transmission again.
Input Setting:
Input Configuration:
Input Function:
Fu252_02g_oi_e.doc / Apr-16
www.hohner-elektrotechnik.de
Description
This register determines the cycle time in seconds for cyclic
transmission when the Printer Mode is switched on.
Range 0.001 to 99.999 seconds.
With setting "0" all cyclic transmission is switched off and the unit will
only send data upon request (PC mode *)
Sets the code of the register of which the content should be sent with
cyclic transmission.
Setting range 00 – 09 (corresponds to register codes :0 to :9)
and 10 - 19 (corresponds to register codes ;0 to ;9)
For clarification of register codes see sections
Sets the switching characteristics of the „Control" input (terminal 10):
0 = function „active HIGH", 1 = function „active LOW"
Selects the function of the "Control" input (terminal 10):
0 =
no control function
1 =
Replaces the frequency applied to input A by a fixed frequency
value as set under parameter „Reset Value A"
2 =
Replaces the frequency applied to input B by a fixed frequency
value as set under parameter „Reset Value B"
3 =
Replaces the result of the combination A / B by a fixed value as
set under parameter „Reset Value A/B"
4 =
Freezes the actual frequency value of input A
5 =
Freezes the actual frequency value of input B
6
Freezes both frequencies A and B
7 =
Starts a serial transmission of the defined register value
10
and 11.