Analog Output Format - Hohner FU 252 Operating Manual

Signal converter for frequency -analog / serial
Table of Contents

Advertisement

5.2.2. Settings for special applications
Where you find that the standard settings shown before are not suitable for your application,
please go through the following setting options and find out the input levels and characteristics
you need.
DIL1
DIL2
5 6 7
3 4 5 6
x
x
0 0 0 1 TTL level (A)
x
x
0 0 1 0 HTL level (A and /A)
x
x
0 0 1 1 TTL level (A)
x
x
0 1 0 0 TTL level (A and /A)
x
x
0 1 0 1 HTL level NPN (A)
x
x
0 1 1 0 HTL level NPN (A)
x
x
0 1 1 1 HTL level NPN (A)
x
x
1 0 0 0 HTL level PNP (A)
x
x
1 0 0 1 HTL level PNP (A)
x
x
1 0 1 0 HTL level PNP (A)
x
x
1 0 1 1 TTL level (A and /A)
x
x
1 1 0 0 TTL level (A)
x
x
1 1 0 1 TTL level (A and /A)
x
x
1 1 1 0 TTL level (A)

5.3. Analog output format

The desired output format of the Analog output can be set by positions 1 and 2 of switch DIL2.
DIL2
Output format
1 2
0 0 Voltage 0 ... +10 V
0 1 Voltage +/- 10 V
1 0 Current 4 – 20 mA
1 1 Current 0 – 20 mA
Fu252_02g_oi_e.doc / Apr-16
www.hohner-elektrotechnik.de
Characteristics of input A
With this setting the format depends on the parameter „Analog
Mode" which can be set by PC. Since the factory default setting
of parameter "Analog Mode" is "1", the format will be a 0 ...
+10 V output under default conditions.
Characteristics of input B
TTL level (B)
HTL level (B and /B)
TTL level (B and /B)
TTL level (B)
HTL level PNP (B)
TTL level (B and /B)
TTL level (B)
TTL level (B and /B)
TTL level (B)
HTL level NPN (B)
HTL level NPN (B)
HTL level NPN (B)
HTL level PNP (B)
HTL level PNP (B)
Page 14 / 36