Daikin E-Series Service Manual page 24

Hide thumbs Also See for E-Series:
Table of Contents

Advertisement

SiBE12-817
Model
Rated Capacity
Front Panel Color
m³/min
Airflow Rates
(cfm)
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Sound Power
H
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.
Specifications
H
M
L
SL
W
Steps
A
W
%
mm
mm
kg
kg
dBA
dBA
mm
mm
mm
FTXS50G2V1B
5.0kW Class
White
10.2 (360)
8.6 (305)
7.0 (246)
6.0 (212)
Cross Flow Fan
23
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable / Washable / Mildew Proof
0.12
26
94.2
Microcomputer Control
295×800×215
274×870×366
10
13
43/39/34/31
59
Both Liquid and Gas Pipes
φ
6.4
φ
9.5
φ
18.0
3D059731
Specifications
50Hz 230V
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
13

Advertisement

Table of Contents
loading

Table of Contents