Durabrand DCT2405R Service Manual page 36

23"
Hide thumbs Also See for DCT2405R:
Table of Contents

Advertisement

Main CBA Bottom View
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
WF6
PIN 3
OF IC801
Downloaded Free from http://www.free-service-manuals.com
CAUTION ! :
For continued protection against risk of fire,
replace only with same type 4 A, 125V fuse.
4A/125V
ATTENTION : Utiliser un fusible de rechange de même type de 4A, 125V.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
8-8
Because a hot chassis ground is present in the power
supply circuit, an isolation transformer must be used.
Also, in order to have the ability to increase the input
slowly,when troubleshooting this type power supply
circuit, a variable isolation transformer is required.
WF8
Q571
Base
WF10
PIN 3
OF WH501A
WF9
PIN 1
OF CN571
WF12
PIN 4
OF CN571
WF7
Q572
Collector
WF11
PIN 7
OF IC551
WF1
PIN 26
OF IC111
WF16
PIN 5
OF TU11
WF2
PIN 14
OF IC111
BL3700F01012-1