Page 1
IVD660-F TYPE: 120 VOLT IN-WALL INSTALLATION IVD660-H SURFACE MOUNTED IF YOU SHOULD HAVE ANY QUESTIONS OR EXPERIENCE A PROBLEM WITH YOUR INTERVAC PRODUCT, DO NOT RETURN THIS PRODUCT TO THE STORE OR DEALER PLEASE CALL US DIRECT 1-888-499-1925 WARNING: Owner read carefully.
Specification: 120 Volt, 12.5 Amp 50/60Hz, Weight 8 lb Parts List: Model IVD660-F MODEL IVD660-H Mounting frame for 2x4 wood studs, 16” on center Steel vacuum hanger + screws 6 screws for installing frame Left and right side panel Slider, pipe connetion...
Page 4
Model 660-H vacuum replacement installation Surface mounted installation with Power Cord attached To remove side panels, loosen the 4 screws inside the vacuum chamber 1) Remove the door from the vacuum, by pulling from the top on the curved bracket. inside you will find: 1 black flanged fitting with 4 screws 1 white reducer...
Page 5
Model IVD 660H Model IVD 660H BACK VIEW OF IVD660-H VACUUM TOP PLATE InterVac Design Corp. Palm City, Florida. 3-1-2017 patent pending 2 1 16 1 1 4 WITH TOP WITHOUT PLATE AND TOP PLATE...
Page 6
WITH TOP WITHOUT PLATE AND TOP PLATE SIDE PANELS AND SIDE ATTACHED UPPER COVERS MOUNTING HOLE MOUNTING BRACKET SIDE PANEL WITH RUBBER PADS SIDE PANEL WITH RUBBER PADS TRACK FOR LOW VOLTAGE WIRE interVac Design Corp. Palm City, Fl. 3-1-2017...
Page 8
Model 660-F new construction installation In-wall installation with Power Cord attached 2 studs have to be on 16” centers. 120 volt 15 amp power receptacle should be in reach of vacuums electrical cord. NOTE: if the studs are on 24 centers, ask the carpenter to install another stud. 2x4 stud wall, without dry-wall installed.
Page 9
Model 660-FR new construction installation In-wall installation with 14 gage Romex Cable GROUNDING INSTRUCTIONS: This appliance must be connected to a grounded metal, permanent wiring system; or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance. WARNING: Disconnect all electrical power to the wall area before installing! An electrician must install the Romex Cable:...
Page 10
PLEASE NOTE: NORMALLY A CENTRAL VACUUM CLEANER IS STARTED WITH THE VACUUM VALVES AROUND THE HOUSE WALLS. WITH THE INTERVAC YOU CAN ALSO UTILIZE THE VALVE IN THE DOOR OF THE POWER UNIT TO CLEAN YOUR GARAGE OR CAR USING THE on/off SWITCH.
Page 11
D: Closing the Door 1. Take the door and open up the cover for the valve opening. 2. Lift the door parallel with the front of the vacuum. Align the hole in the door with the hole in the bag collar. You have to look through the valve hole and push door in position.
Page 12
PART # AS11 " VacPort.com ” for RM Models Elongated Dust Brush Air Turbo Nozzle Model A910 w/o LED light PART # X251 PART # X451 Model A900 with LED light INTERVAC reserves the right to make improvements and modifications without notice.
Need help?
Do you have a question about the IVD660-F and is the answer not in the manual?
Questions and answers