Serious injury could occur if you connect
the machine to power before completing the
setup process. DO NOT connect to power
until instructed later in this manual.
Circuit Requirements for G0453
Nominal Voltage ........................................240V
Cycle ..........................................................60 Hz
Phase ........................................... Single-Phase
Circuit Rating ...............................................20A
Plug/Receptacle ............................. NEMA 6-20
GROUNDED
6-20 RECEPTACLE
6-20 PLUG
1
Figure
.
No adapter should be used with the
required plug. If the plug does not fit the
available receptacle, or the machine must
be reconnected for use on a different type
of circuit, the reconnection must be made
by a qualified electrician and comply with all
local codes and ordinances.
Circuit Requirements for G0454
Nominal Voltage ........................................240V
Cycle ..........................................................60 Hz
Phase ........................................... Single-Phase
Circuit Rating ...............................................30A
Plug/Receptacle ...........................NEMA L6-30
L6-30 GROUNDED
LOCKING
RECEPTACLE
L6-30
LOCKING
PLUG
Figure 2.

Extension Cords

Minimum Gauge Size ...........................14 AWG
Maximum Length (Shorter is Better).......50 ft.