GenICam parameters to set:
I / O Controls > Trigger Mode > Off
•
•
Camera Control > Internal Line Rate > user value
Camera Control > Exposure Time > user value
•
External Programmable Exposure
The External Programmable Exposure mode is similar to Internal Programmable except for the
exposure start being an external user input.
•
The TriggerSource feature (see I/O Control category) selects an external signal line as trigger.
Line rates and exposure limits are as defined for Internal Programmable Exposure.
•
The falling edge of the EXSYNC (CC1) signal triggers the start of the internal exposure.
•
CC1
Programmable Exposure
1.
Exposure time > 4µs
2.
Sensor readout time = 20.8 µs
3.
LVAL delay = 41µs
GenICam parameters to set:
I / O Controls > Trigger Mode > On
•
•
Camera Control > Exposure Time Source > Timed
Camera Control > Exposure Time > user value
•
Linea CLHS Series Camera
Line Time
> 2 µs
1
Programmable Exposure
2
Sensor Readout
LVAL
3
LVAL delay
1
Programmable Exposure
2
Sensor Readout
Camera Operation
1
2
Sensor Readout
33
•