GenICam parameters to set:
I / O Controls > Trigger Mode > Off
Camera Control > Internal Line Rate > user value
Camera Control > Exposure Time > user value
External Programmable Exposure
The External Programmable Exposure mode is similar to Internal Programmable except for the
exposure start being an external user input.
The TriggerSource feature (see I/O Control category) selects an external signal line as trigger.
Line rates and exposure limits are as defined for Internal Programmable Exposure.
The falling edge of the EXSYNC (CC1) signal triggers the start of the internal exposure.
CC1
Programmable Exposure
1.
Exposure time > 4µs
2.
Sensor readout time = 20.8 µs
3.
LVAL delay = 41µs
GenICam parameters to set:
I / O Controls > Trigger Mode > On
Camera Control > Exposure Time Source > Timed
Camera Control > Exposure Time > user value
Linea CLHS Series Camera
Line Time
> 2 µs
1
Programmable Exposure
2
Sensor Readout
LVAL
3
LVAL delay
1
Programmable Exposure
2
Sensor Readout
Camera Operation
1
2
Sensor Readout
33