After several seconds the PRNU calibration will end and the correction coefficients will be
•
enabled. The system gain remains as first set.
The coefficients and gain parameters, timing and control configuration can be stored in any
•
one of eight user sets and automatically retrieved at power-up or by user selection.
CamExpert has a default timeout of 20 seconds per command, which is too
short for the FFC calibration to run fully. You can change the default timeout by
setting a command line argument in the short-cut:
Right-click on the short-cut in the start menu and select Properties.
•
In the Target field, add the switch –timeout 60 (See below)
•
This increases the command timeout to 60 seconds.
Note that you must include a character space between the closing
quotation mark in the target and the hyphen before the timeout value.
Repeat for desktop short-cut
•