4.2. Status Messages

This section defines status messages that are sent from the module back to the host over the
serial port.
The status message begins with the ASCII characters "STA " an as defined in the
Commands
Code
Status
0000
Device reset

4.3. Error Messages

This section defines the error messages that are sent from the module back to the host over
the serial port. The message begins with the ASCII characters "ERR" as defined in the
Commands
Code
Error
0003
Not Ready for new
commands
0004
Incorrect command
format
0009
Not ASCII coded
hex
000a
Command not
recognized
0012
Invalid parameter
0017
Radio init failed
0018
Radio receive
overflow
C
© 2017, R
OPYRIGHT
ADIO
Note that status messages do not include errors. Error messages are defined
in the section
Error
Messages.
section. These error codes are defined in the following table.
Table 11 Status Messages
Description
Device just came out of reset
section. This error codes are defined in the following table:
Table 12 Error Messages
Description
The host is attempting to send new commands but the
device is not ready to receive new commands yet.
The format of the serial command sent to the device is
wrong.
The values provided were not ASCII coded hex values.
A command was sent to the device that was not
recognized
The parameter used in the AT command is invalid
Initialization of the radio failed
Radio receiver overflow condition, radio is reset
B
I
.
RIDGE
NC
R
B
ADIO
RIDGE
R
B
RBM101
U
ADIO
RIDGE
I
RBM101
U
G
I
SER
UIDE
Serial
Serial
G
P
14
19
SER
UIDE
AGE
OF

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rbm101h-345

Table of Contents